JVC-RXE12B-hccc-sm维修电路原理图.pdf
《JVC-RXE12B-hccc-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-RXE12B-hccc-sm维修电路原理图.pdf(96页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COPYRIGHT 2005 Victor Company of Japan, Limited No.MB387 2005/2 HOME CINEMA CONTROL CENTER MB38720052 RX-E11S,RX-E12B TABLE OF CONTENTS 1PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . 1-3 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . . . 1-6 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16 5TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、 . . . . . . . . 1-17 Area suffix B - U.K. E - Continental Europe EN - Northern Europe EV - Eastern Europe RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB387) SPECIFICATION * Corresponding to Linear PCM, Dolby Digital, and DTS (with sampling frequency-32 kHz, 44.1 kHz, 48 kHz). Design and specifications are subj
5、ect to change without notice. Amplifier Output PowerAt stereo operationFront channels60 W per channel, min. RMS, both channels driven into 6 at 1 kHz with no more than 10% total harmon- ic distortion. (IEC268-3) At surround operationFront channels60 W per channel, min. RMS, driven into 6 at 1 kHz wi
6、th no more than 10% total harmonic distortion. Center channel60 W, min. RMS, driven into 6 at 1 kHz, with no more than 10% total harmonic distortion. Surround channels60 W per channel, min. RMS, driven into 6 at 1 kHz, with no more than 10% total harmonic distortion. AudioAudio Input Sensitivity/Im-
7、 pedance DVR/DVD, VCR, TV, VIDEO170 mV(p-p)/47 k Audio Input (DIGITAL IN)* Coaxial: DIGITAL IN 1(DVR/DVD)0.5 V(p-p)/75 Optical: DIGITAL IN 2(VIDEO)-21 dBm to -15 dBm (660 nm 30 nm) Audio Output LevelDVR/DVD, VCR, TV170 mV Signal-to-Noise Ratio (66 IHF/DIN)87 dB/62 dB Frequency Response (6 )20 Hz to
8、20 kHz (1 dB) Bass Boost+4 dB 1 dB at 100 Hz EqualizationCenter frequency63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHz Control range8 dB VideoVideo Input Sensitivity/Im- pedance Composite video:DVR/DVD, VCR, TV, VIDEO 1 V(p-p)/75 S-video:DVR/DVD, VCRY (luminance):1 V(p-p)/75 C (chrominance, burst):0.3 V(p-p)/
9、75 RGB:DVR/DVD, VCR0.7 V(p-p)/75 Component:DVR/DVDY (luminance):1 V(p-p)/75 PB, PR:0.7 V(p-p)/75 Video Output Level/Im- pedance Composite videoDVR/DVD, VCR, TV1 V(p-p)/75 S-video: TVY (luminance):1 V(p-p)/75 C (chrominance, burst):0.3 V(p-p)/75 RGB:TV0.7 V(p-p)/75 Component:MONITOR OUTY (luminance):
10、1 V(p-p)/75 PB, PR:0.7 V(p-p)/75 SynchronizationNegative FM tuner (IHF) Tuning Range87.50 MHz to 108.00 MHz Usable Sensitivity Monaural17.0 dBf (1.95 V/75 ) 50 dB Quieting Sensitivity Monaural21.3 dBf (3.2 V/75 ) Stereo41.3 dBf (31.5 V/75 ) Stereo Separation at Rec Out35 dB at 1 kHz AM (MW) tuner Tu
11、ning Range522 kHz to 1 629 kHz General Power RequirementsAC 230 V , 50 Hz Power Consumption120 W (at operation) 1 W (in standby mode) Dimensions (W H D)435 mm 70 mm 325 mm Mass5.6 kg RadioFans.CN 收音机爱 好者资料库 (No.MB387)1-3 SECTION 1 PRECAUTIONS 1.1Safety Precautions (1) This design of this product con
12、tains special hardware and many circuits and components specially for safety purpos- es. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services s
13、hould be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture
14、of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related characteristics. These characteris- tics are often not evident from visual inspection nor can the protection afforded by them necessarily
15、 be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser- vice Manual. Electrical components having such features are identified by shading on the schematics and
16、by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac- teristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. (4) The leads in the products are routed
17、and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should
18、 be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing After reassembling the product, always perform an isola- tion check on the exposed metal parts of the product (an- tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control
19、shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the ca
20、binet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 per volt or more sensit
21、ivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- posed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly a
22、ny exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipmen
23、t has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained. (3) Repairs must be made in accordance with the relevant safety standards. (4) It is essential that safety critical co
24、mponents are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage. 1.3Caution Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of pre- forming repair of this system. 1.4Crit