JVC-MXKB4-cs-sm维修电路原理图.pdf
《JVC-MXKB4-cs-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-MXKB4-cs-sm维修电路原理图.pdf(55页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COPYRIGHT 2004 VICTOR COMPANY OF JAPAN, LIMITED No.MB196 2004/6 COMPACT COMPONENT SYSTEM MB19620045 MX-KB4 TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
2、 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-
3、7 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 5TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . . . 1-21 FM MODEFM /AM AUX SLEEP STANDBY/ON CD1CD2CD3 SOUND MODE RHYTHM AX FADE MUTING VOLUME PROGRAM/RANDOMREPEAT TAPEA CD TAPEB REMOTE CONTROL CA-MXKB4SP-MXKB4SP-MXKB4 Area suffix J - U.S.A. C - Canada RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB196) SPECIFICATION Design and specifications are subject t
5、o change without notice. AmplifierOutput Power180 W per channel, min. RMS, driven into 6 at 1kHz, with no more than 10% total harmonic distortion Input Sensitivity/Impedance (1 kHz) AUX IN:400 mV/50 k Speaker terminals6 - 16 Phones32 - 1 k Cassette DeckFrequency Response15 mW/ch output into 32 Type
6、I (NORMAL)63 Hz - 12 500 Hz Wow And Flutter0.15% (WRMS) CD PlayerCD Capacity3 CDs Dynamic Range85 dB Signal-To-Noise Ratio85 dB Wow And FlutterUnmeasurable TunerFM TunerTuning Range:87.5 MHz - 108.0 MHz AM TunerTuning Range:530 kHz - 1 710 kHz UnitDimensions270 mm 306 mm 456 mm (W/H/D) (10-11/16 12-
7、1/16 18) MassApprox. 8.6 kg (19.0 lbs) Speaker Specifications SP-MXKB4 (each unit) Type3-way bass-reflex type Speaker UnitWoofer:20 cm (7-7/8) cone 1 Mid:5cm (2) cone 1 Tweeter:2 cm (13/16) dome 1 Power Handling Capacity180 W Impedance6 Frequency Range45 Hz - 22,000 Hz Sound pressure level87 dB/Wm D
8、imensions257 mm 321 mm 261 mm (W/H/D) (10-1/8 12-11/16 10-5/16) MassApprox. 4.9 kg (10.9 lbs) Power SpecificationsPower RequirementsAC 120 V , 60 Hz Power Consumption150 W (power on mode) 22 W (in Standby mode) RadioFans.CN 收音机爱 好者资料库 (No.MB196)1-3 SECTION 1 PRECAUTION 1.1Safety Precautions (1) This
9、 design of this product contains special hardware and many circuits and components specially for safety purpos- es. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the or
10、iginal circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will furth
11、er relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related characteristics. These characteris- tics are often not evident from visual inspection nor can the protection a
12、fforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser- vice Manual. Electrical components having such features are identified by sha
13、ding on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac- teristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. (4) The leads
14、in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should
15、 be observed, and it should be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing After reassembling the product, always perform an isola- tion check on the exposed metal parts of the product (an- tenna terminals, knobs, metal cabinet, screw head
16、s, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each ex
17、posed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,
18、000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- posed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed
19、 metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1
20、.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained. (3) Repairs must be made in accordance with the relevant safety standards. (4) It is essent
21、ial that safety critical components are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage. 1.3Caution Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of pre- forming rep
22、air of this system. 1.4Critical parts for safety In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearby are critical for saf
23、ety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version) Good earth ground Place this probe on each exposed metal part. AC VOLTMETER (Having 1000 ohms/volts, or more sensitivity) 1500 10W 0.
24、15 F AC TYPE 1-4 (No.MB196) 1.5Preventing static electricity Electrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when performing repairs. 1.5.1
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JVC MXKB4 cs sm 维修 电路 原理图