1、SERVICE MANUAL COPYRIGHT 2004 VICTOR COMPANY OF JAPAN, LIMITED No.MB157 2004/2 COMPACT COMPONENT SYSTEM MB15720042 MX-KB30 TABLE OF CONTENTS 1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-
2、3 2SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 3DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
3、-7 4ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 5TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、 . . . . 1-21 Area Suffix J - U.S.A. C - Canada FM MODEFM /AM AUX SLEEP STANDBY/ON CD1CD2CD3 SOUND MODE ACTIVE BASS EX. SOUND TURBO FADE MUTING VOLUME PROGRAM/RANDOMREPEAT TAPE A/B TAPE CD CA-MXKB30SP-MXKB30SP-MXKB30 RadioFans.CN 收音机爱 好者资料库 1-2 (No.MB157) SPECIFICATION Design and specifications are
5、subject to change without notice. AmplifierOutput Power150 W per channel, min. RMS, driven into 6 at 1kHz, with no more than 10% total harmonic distortion Input Sensitivity/Impedance (1 kHz) AUX IN : 300 mV/50 k Speaker terminals6 - 16 Phones32 - 1 k 15 mW/ch output into 32 63 Hz - 12 500 Hz Cassett
6、e DeckFrequency Response Type I (NORMAL) Wow And Flutter0.15% (WRMS) CD PlayerCD Capacity3 CDs Dynamic Range85 dB Signal-To-Noise Ratio85 dB Wow And FlutterUnmeasurable TunerFM TunerTuning Range : 87.5 MHz - 108.0 MHz AM TunerTuning Range : 530 kHz - 1 710 kHz UnitDimensions267 mm 305 mm 433 mm (W/H
7、/D) (10-9/16 12-1/16 17-1/16) MassApprox. 8.7 kg (19.2 lbs) Speaker Specifications (each unit) SP-MXKB303-way bass-reflex type TypeWoofer: 16 cm (6-5/16) cone 1 Speaker UnitMid: 5cm (2) cone 1 Tweeter: 2 cm (13/16) dome 1 Power Handling Capacity150 W Impedance6 Frequency Range45 Hz - 22,000 Hz Sound
8、 pressure level87 dB/Wm Dimensions244 mm 321 mm 258 mm (W/H/D) (9-5/8 12-11/16 10-3/16) MassApprox. 3.6 kg (8.0 lbs) Power SpecificationsPower RequirementsAC 120 V , 60 Hz Power Consumption135 W (power on mode) 18 W (in Standby mode) RadioFans.CN 收音机爱 好者资料库 (No.MB157)1-3 SECTION 1 PRECAUTION 1.1Safe
9、ty Precautions (1) This design of this product contains special hardware and many circuits and components specially for safety purpos- es. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical
10、to those used in the original circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers
11、warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical parts in the products have special safety-related characteristics. These characteris- tics are often not evident from visual inspection n
12、or can the protection afforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser- vice Manual. Electrical components having such feature
13、s are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac- teristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other
14、hazards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead r
15、outing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing After reassembling the product, always perform an isola- tion check on the exposed metal parts of the product (an- tenna terminals, knobs, me
16、tal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leaka
17、ge current from each exposed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an
18、AC voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- posed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor con
19、nection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds t
20、o 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of the repairer to ensure that these safety standards are maintained. (3) Repairs must be made in accordance with the relevant safety stan
21、dards. (4) It is essential that safety critical components are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage. 1.3Caution Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the c
22、ase of pre- forming repair of this system. 1.4Critical parts for safety In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark near
23、by are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version) Good earth ground Place this probe on each exposed metal part. AC VOLTMETER (Having 1000 ohms/volts, or more s
24、ensitivity) 1500 10W 0.15 F AC TYPE 1-4 (No.MB157) 1.5Preventing static electricity Electrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laser diode in the traverse unit (optical pickup). Take care to prevent this when pe