JVC-FSH35-cs-sm维修电路原理图.pdf
《JVC-FSH35-cs-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-FSH35-cs-sm维修电路原理图.pdf(69页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUAL COPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LIMITED No.22063 2003/5 COMPACT COMPONENT SYSTEM 2206320035 FS-H35 TABLE OF CONTENTS 1Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、 1-3 2Disassembly method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 3Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . . . . . . 1-19 4Description of major ICs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-25 COMPACT COMPONENT SYSTEM Area Suffix J - U.S.A. C - Canada RadioFans.CN 收音机爱 好者资料库 1-2 (No.22063) SPECIFICATION Design
4、and specifications are subject to change without notice. AmplifierOutput Power20 W (10 W + 10 W) at 4 (10% THD) 12 W per channel, min. RMS, driven into 4 at from 80 Hz to 15 kHz with no more than 10% total harmonic distortion. Audio input sensitivity/Impedance (at 1 kHz)AUX500 mV/48.75 k Speakers/Im
5、pedance4 TunerFM tuning range87.5 MHz - 108.0 MHz AM tuning range530 kHz - 1 710 kHz CD playerDynamic range85 dB Signal-to-noise ratio90 dB Wow and flutterImmeasurable Cassette deckFrequency responseNormal (type I)50 Hz - 15 000 Hz Wow and flutter0.15% (WRMS) SpeakerSpeaker unitsFull range8.0 cm (3
6、3/16 in.) cone 1 Impedance4 Dimensions (approx.)135 mm 203 mm 190 mm (W/H/D) (5 3/8 in. 8 in. 7 1/2 in.) Mass (approx.)1.7 kg (3.8 lbs) each GeneralPower requirementAC IN120, 60 Hz DC IN12 V, 4 A Power consumption35 W (at operation) 3.0 W (on standby) Dimensions (approx.)412 mm 208 mm 275 mm (W/H/D)
7、 (16 1/4 in. 8 1/4 in. 10 7/8 in.) Mass (approx.)6.5 kg (14.4 lbs) RadioFans.CN 收音机爱 好者资料库 (No.22063)1-3 SECTION 1 Precautions 1.1Safety Precautions (1) This design of this product contains special hardware and many circuits and components specially for safety purpos- es. For continued protection, n
8、o changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be per- formed by qualified personnel only. (2) Alterations of the design or circuitry of the product should n
9、ot be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom. (3) Many electrical and mechanical par
10、ts in the products have special safety-related characteristics. These characteris- tics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by us- ing replacement components rated for higher voltage, watt- age, etc. Replacement parts which hav
11、e these special safety characteristics are identified in the Parts List of Ser- vice Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same saf
12、ety charac- teristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards. (4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature part
13、s, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem- bling. (5) Leakage shock hazard testing After r
14、eassembling the product, always perform an isola- tion check on the exposed metal parts of the product (an- tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolati
15、on transformer during this check. Plug the AC line cord directly into the AC outlet. Using a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particular- ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any
16、leakage cur- rent must not exceed 0.5mA AC (r.m.s.). Alternate check method Plug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15F AC-type capacitor between an ex- p
17、osed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reve
18、rse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). 1.2Warning (1) This equipment has been designed and manufactured to meet international safety standards. (2) It is the legal responsibility of t
19、he repairer to ensure that these safety standards are maintained. (3) Repairs must be made in accordance with the relevant safety standards. (4) It is essential that safety critical components are replaced by approved parts. (5) If mains voltage selector is provided, check setting for local voltage.
20、 1.3Caution Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of pre- forming repair of this system. 1.4Critical parts for safety In regard with component parts appearing on the silk-screen printed side (parts side) of the P
21、WB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the mark nearby are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (This regulation dose not Exce
22、pt the J and C version) Good earth ground Place this probe on each exposed metal part. AC VOLTMETER (Having 1000 ohms/volts, or more sensitivity) 1500 10W 0.15 F AC TYPE 1-4 (No.22063) 1.5Importance administering point on the safety Caution: For continued protection against risk of fire, replace onl
23、y with same type 1A/125V for F901, 6.3A/125V for F902 and F903. This symbol specifies type of fast operating fuse. Precaution: Pour eviter risques de feux, remplacez le fusible de surete de F901 comme le meme type que 1A/125V, et 6.3A/125V pour F902 et F903. Ce sont des fusibles suretes qui function
24、nes rapide. C902 C901 C903 C904 CN901 D901 D902 D904 D903 D905 Z901 Z913 Z902 T901 J902 L901 R901 S901 Z912 B908 Z903 Z911 PP901 B910 B911 B914 B913 B916 B902 B901 B903 B904 B909 B907 B912 J901 B915 (No.22063)1-5 1.6Preventing static electricity Electrostatic discharge (ESD), which occurs when stati