JBL-E150P-pwr-sm维修电路原理图.pdf
《JBL-E150P-pwr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JBL-E150P-pwr-sm维修电路原理图.pdf(28页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Northridge E-Series E150P Powered Subwoofer Service Manual JBL Consumer Products 250 Crossways Park Dr. Woodbury, New York 11797 Rev2 2/2004 RadioFans.CN 收音机爱 好者资料库 - CONTENTS - BASIC SPECIFICATIONS .1 SAFETY INFORMATION .2 DETAILED SPECIFICATIONS .3 CONNECTIONS.4 OPERATION .7 BASIC TROUBLESHOOTING
2、.8 EXPLODED VIEW/PARTS LIST.9 TEST SET-UP AND PROCEDURE.10 AMPLIFIER BLOCK DIAGRAM.11 TECH TIP JBLTT2003-04 .12 DETAILED TROUBLESHOOTING. 13 P.C.B. DRAWINGS.16 ELECTRICAL PARTS LIST .20 IC/TRANSISTOR PINOUTS.24 SCHEMATICS.25 PACKING.27 E150P SPECIFICATIONS Amplifier Power (RMS): 150 Watts Peak Dynam
3、ic Power *: 250 Watts Driver: 10 (254mm) PolyPlas Inputs: Line Level (switchable to LFE) and Speaker Level with 5-way binding posts Low-Pass Frequency: Variable from 50Hz to 150Hz Frequency Response: 27Hz Low-pass crossover setting Dimensions (H x W x D): 17-3/4 x 12-1/4 x 14-1/2 (451mm x 311mm x 36
4、8mm) Weight: 33.5 lb/15.2kg JBL continually strives to update and improve existing products, as well as create new ones. The specifications and details in this and related JBL publications are therefore subject to change without notice. * The Peak Dynamic Power is measured by recording the highest c
5、enter-to-peak voltage measured across the output of a resistive load equal to minimum impedance of the transducer, using a 50Hz sine wave burst, 3 cycles on, 17 cycles off. E150P E150P 1 RadioFans.CN 收音机爱 好者资料库 Warning Any person performing service of this unit will be exposed to hazardous voltages
6、and the risk of electric shock. It is assumed that any person who removes the amplifier from this cabinet has been properly trained in protecting against avoidable injury and shock. Therefore, any service procedures are to be performed by qualified service personal ONLY! Caution Early revisions of t
7、he unit did not have a power switch. Hazardous voltages are resent within the unit whenever it is plugged in. Before amplifier is plugged in, be sure its rated voltage corresponds to the voltage of the AC power source to be used. Incorrect voltage could cause damage to the amplifier when the AC powe
8、r cord is plugged in. Do not exceed rated voltage by more than 10%: operation below 90% of rated voltage will cause poor performance or may shut the unit off. Leakage/Resistance Check Before returning the unit to the customer, perform a leakage or resistance test as follows: Leakage Current. Note th
9、ere is no power switch on early revisions of this unit. When the power plug is plugged in, the unit is live. Connect the unit to its rated power source. Using an ammeter, measure the current between the neutral side of the AC supply and chassis ground of the unit under test. If leakage current excee
10、ds 0.5mA, the unit is defective. Reverse the polarity of the AC supply and repeat. Resistance. Measure the resistance from either side of the line cord to chassis ground, If it is less than 500k ohms, the unit is defective. WARNING! DO NOT return the unit to the customer if it fails one of these tes
11、ts until the problem is located and corrected. Critical Components All components identified with the IEC symbol in the parts list and schematic diagram designate components in which safety can be of special significance when replacing identified with. Use only the replacement parts designated in th
12、e parts list or parts with the same rating of resistance, wattage or voltage. SAFETY INFORMATION List of Safety Components Requiring Exact Replacements Part Number/ Designator Description F1 093-205209-300 Line Fuse Slo Blo 1.25A 5x20mm 083-041802-009 250V UL approved SPT-2 or better with polarized
13、plug, UL approved wired with the hot side to fused side. Use with factory replacement panel strain relief (70305) only. PT1 042-010052-003 Power Transformer. Use only factory replacement. BR1 052-400080-000 Bridge diode. Use only factory replacement. C6,8 034-470745-200 4700uF 50V electrolytic filte
14、r caps. Be sure replacement part is at least the same working voltage and capacitance rating. Also the lead spacing is important. Incorrect spacing may cause premature failure due to internal cabinet pressure and vibration. 063-531808-000 Rear Amp Cover Use only factory replacement Inductor 043-5602
15、00-000 L1 - Use only factory replacement Inductor 043-300101-000 L2 - Use only factory replacement Inductor 043-700101-000 L3 - Use only factory replacement Inductor 043-324300-000 L4 - Use only factory replacement E150P 2 JBL E150P Powered Sub/ Plate Amp LINE VOLTAGEYes/NoHi/Lo LineNom.UnitNotes US
16、 120vac/60HzYes108-132120VrmsNormal Operation EU 230vac/50-60HzYes207-264230VrmsNormal operation, MOMS required ParameterSpecificationUnit QA Test LimitsConditionsNotes Amp Section Type (Class AB, D, other)Dn/an/aClass D Preferred.Sink required for Class AB Load Impedance (speaker)4Ohmsn/aNominalZ-c
17、urve required Rated Output Power75Watts701 input driven AVG RMS Dynamic Power150Watts135 Average RMS power, 3/20 Cycles 50 Hz, Driven 6dB above its input sensitivity sensitivity THD Rated Power0.3%122k filter75 Watts THD 1 Watt0.1%0.522k filter DC Offset10mV-DC30 Speaker Outputs Damping factor50DF35
18、Measured at amplifier board Measured at the amplifier board THD 4.7Kohmsn/aNominal Filters Speaker in LP 2nd order varia60-150 Hz 10 Subsonic filter (HPF) fixed 6thFixed LFE Low pass 2nd order fixed200LP T T 1M (NO LOAD) Resistance from V+ (C6 P+) to V- (C8 P-) gradually Fully CHARGED should read 10
19、k Resistance from V+ (C6 P+) to S+ (SPK O/P) should read 1M Resistance from V- (C8 P-) to S+ (SPK O/P) should read 1M 2. Power UpLED RED With a 5mV signal to Low level input, LED should change to GREEN -Voltage measurements (DVM) OP AMP LEDP-U4(1)P-U4(7) RED0Vrms8VDC GREEN6.3Vrms-10.7VDC 3. D.C. Ope
20、ration -Voltage measurements (DVM) on CLASS D POWER AMP BetweenV+Q4(E)Q1(C)Q10(C)U7(1)U7(2)U7(4)U7(6)U7(7)U7(8) And This Point GNDV-GNDGNDGNDGNDGNDGNDGNDGND Get this Reading 45.9V0V-45.9V0V-45.9V-45.7V-45.5V0V0V4.7V 4. Check Switching Frequency Oscilloscope - USE THE PROBE TIP TO U6(7) TO GND Readin
21、g 100kHz +/-10%,22Vp-p B. Pre Amp Section Line Level Input Sensitivity -Set upTurn level, XOVER FREQ POT Fully CW and LFE switch off Generator Set at 100mV50Hz Signal to Line level input E150P E150P DETAILED TROUBLESHOOTING 13 - Voltage measurements OP AMP U2(1)U2(14)U2(8)U3(7)U3(1)U3(14)U3(8)U5(7)U
22、5(1) SPEAKER O/P 133.6mV200.2mV245.9mV314.8mV314.9mV350mV1.67V1.452V2.098V15.3V 2. High Level Input Sensitivity -Set upTurn level, XOVER FREQ POT Fully CW and LFE switch off Set Generator at 1.15V50Hz Signal to High level input -Voltage measurements 15.3V at speaker output 3. Low-Pass -Set upSet Gen
23、erator at 100 mV100Hz Signal to Line level input Measure voltage at S+ speaker output -Voltage measurement XOVER FREQ. SettingOutput CW10.72V CCW2.165V 4. LFE -Set upSet Generator at 100mV200Hz Signal to Line level input Measure voltage at S+ speaker output LFE switch SettingOutput Normal2.9V LFE7.6