Hitachi-DVP705U-cd-sm维修电路原理图.pdf
《Hitachi-DVP705U-cd-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Hitachi-DVP705U-cd-sm维修电路原理图.pdf(41页珍藏版)》请在收音机爱好者资料库上搜索。
1、TK No.9010E SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT DVD PLAYER SERVICE MANUAL 2000SeptemberDigital Media Products Division, Tokai DV-P705E DV-P705E(UK) DV-P705U DVD/CD/VIDEO CD PLAYER DV-P705 VIRTUAL SURROUNDOPEN/CLOSE DISC NAVIGATION TOP MENU PUSH ENTER MENU STOP SKIP FWD REV
2、 PLAY/ PAUSE /I RadioFans.CN 收音机爱 好者资料库 PRODUCT SAFETY NOTICE Many electrical and mechanical parts have special safety-related characteristics. These are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for
3、 a higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in this Service Manual. Electrical components having such features are identified by marking with a on the schematics and the parts list in this Service Manual. The use of a substitute r
4、eplacement component which does not have the same safety characteristics as the HITACHI recommended replacement one, shown in the parts list in this Service Manual, may create shock, fire, or other hazards. Product safety is continuously under review and new instructions are issued from time to time
5、. For the latest information, always consult the current HITACHI Service Manual. A subscription to, or additional copies for, HITACHI Service Manual may be obtained at a nominal charge from HITACHI SALES CORPORATION. LASER RADIATION Do not stare at the laser beam CAUTION RadioFans.CN 收音机爱 好者资料库 NOTI
6、CE: Comply with all cautions and safety related notes located on or inside the cabinet and on the chassis. 1. When replacing a chassis in the instrument, all the protective devices must be put back in place, such as barriers, non-metallic knobs, adjustment and compartment covers/shields, isolation r
7、esistors/ capacitors, etc. 2. When service is required, observe the original lead- ress. Extra precautions should be taken to assure correct lead dress in the high voltage circuit. 3. Always use the manufacturers replacement components. Especially critical components as indicated on the circuit diag
8、ram should not be replaced by other manufacturers. Furthermore, where a short-circuit has occurred, replace those components that indicate evidence of overheating. 4. Before returning an instrument to the customer, the service technician must thoroughly test the unit to be certain that it is complet
9、ely safe to operate without danger of electrical shock, and be sure that no protective device built into the instrument by the manufacturer has become defective or inadvertently defeated during servicing. Therefore, the following checks should be performed for the continued protection of the custome
10、r and service technician. Leakage Current Cold Check With the AC plug removed from the AC120V, 60Hz source, place a jumper across the two plug prongs. Turn the AC power switch on. Using an insulation tester (DC500V), connect one lead to the jumpered AC plug and touch the other lead to exposed metal
11、parts (antennas, screwheads, metal overlays, control shafts, etc.), particularly any exposed metal part having a eturn path to the chassis. Exposed metal parts having a return path to the chassis should have a minimum resistor reading of 0.3 Mohm and a maximum resistor reading of 5 Mohm. Any resisto
12、r value below or above this range indicates an abnormality which requires corrective action. Exposed metal parts not having a return path to the chassis will indicate an open circuit. Leakage Current Hot Check Plug the AC line cord directly into a AC120V, 60Hz outlet (do not use an isolation transfo
13、rmer for this check). Turn the AC power switch on. Using a Leakage Current Tester, measure for current from all exposed metal parts of the cabinet (antennas, screwheads, metal overlays, control shaft, etc.), particularly an exposed metal part having a return path to the chassis, to a known ground (e
14、arth) (water pipe, conduit, etc.). Any current measured must not exceed 0.5 mA. SAFETY PRECAUTIONS AC Leakage Test ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURNING THE UNIT TO THE CUSTOMER. PRODUCT SAFETY NOTICE M
15、any electrical and mechanical parts have special safety- related characteristics. These are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for a higher voltage, wattage, etc. Replacement parts which have
16、these special safety characteristics are identified in this Service Manual. Electrical components having such features are identified by marking with aon the schematics and the parts list in this Service Manual. The use of a substitute replacement component which does not have the same safety charac
17、teristics as the HITACHI recommended replacement one, shown in the parts list in this Service Manual, may create shock, fire, or other hazards. Product safety is continuously under review and new instructions are issued from time to time. For the latest information, always consult the current HITACH
18、I Service Manual. A subscription to, or additional copies for, HITACHI Service Manual may be obtained at a nominal charge from HITACHI SALES CORPORATION. DEVICE UNDER TEST (READING SHOULD NOT BE ABOVE 0.5mA) LEAKAGE CURRENT TESTER TEST ALL EXPOSED METAL SURFACES 2-WIRE CORD ALSO TEST WITHPLUG REVERS