HarmanKardon-AVR300-avr-sm维修电路原理图.pdf
《HarmanKardon-AVR300-avr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《HarmanKardon-AVR300-avr-sm维修电路原理图.pdf(91页珍藏版)》请在收音机爱好者资料库上搜索。
1、harman/kardon AVR300 A/V DOLBY DIGITAL RECEIVER SERVICE MANUAL CONTENTS SPECIFICATIONS.2 ESD WARNING. .4 LEAKAGE TESTING.5 CONTROLS AND FUNCTIONS. .6 SERVICE PROCEDURE.9 ALIGNMENT PROCEDURE. .9 IDLE CURRENT/DC OFFSET.10 ALIGNMENT/TEST POINTS. 11 CIRCUIT DESCRIPTION. 13 BLOCK DIAGRAM 16 BULLETIN HK20
2、00-05. 17 BULLETIN HK2000-02 Rev1.18 DISASSEMBLY PROCEDURE.21 UNIT EXPLODED VIEW.22 MECHANICAL PARTS LIST.23 PCB DRAWINGS25 ELECTRICAL PARTS LIST.30 INTEGRATED CIRCUIT DRAWINGS.52 SCHEMATICS.80 SEMICONDUCTOR PINOUTS.89 WIRING DIAGRAM.90 PACKAGE.91 harman/kardon, Inc. 250 Crossways Park Dr. Woodbury,
3、 New York 11797Rev0 6/2002 RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 Eachprecautioninthismanualshouldbefollowedduringservicing. Components identified with the IEC symbolin the parts list are special significance to safety. When replacing a component identified with , us
4、e only the replacement parts designated, or parts with the same ratings or resistance, wattage, or voltage that are designated in the parts list in this manual. Leakage-current or resistance measurements must be made to determine that exposed parts are acceptably insulated from the supply circuit be
5、fore retuming the product to the customer. Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field effect transistors and
6、semiconductor chip components. The following techniques should be used to help reduce the incidence of component damage caused by static electricity. 1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any electrostatic charge on your body by touc
7、hing a known earth ground. Alternatively, obtain and wear a commercially available discharging wrist strap device, which should be removed for potential shock reasons prior to applying power to the unit under test. 2. After removing an electrical assembly equipped with ES devices, place the assembly
8、 on a conductive surface such as aluminum foil, to prevent electrostatic charge build-up or exposure of the assembly. 3. Use only a grounded-tip soldering iron to solder or unsolder ES devices. 4. Use only an anti-static solder removal device. Some solder removal devices not classified as anti-stati
9、c can generate electrical charges sufficient to damage ES devices. 5. Do not use freon-propelled chemicals. These can generate electrical change sufficient to damage ES devices. 6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it.
10、 (Most replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable conductive material.) 7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material to the chassis or
11、circuit assembly into which the device will be installed. Be sure no power is applied to the chassis or circuit, and observe all other safety precautions. 8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the brushing together or your clot
12、hes fabric or the lifting of your foot from a carpeted floor can generate static electricity sufficient to damage an ES devices. CAUTION : - 4 - 300RadioFans.CN 收音机爱 好者资料库 1. lnspect all lead dress to make certain that leads are not pinched or that hardware is not lodged between the chassis and othe
13、r metal partsintheunit. 2. Be sure that any protective devices such as nonmetallic control knobs, insulating fish- papers,cabinetbacks,adjustmentand compartment covers or shields, isolation resistor-capacitynetworks,mechanical insulators, etc. Which were removed for the servicingareproperlyre-instal
14、led. Before returning the unit to the user, perform the following safety checks : 3. Be sure that no shock hazard exists ; check for leakage currentusingSimpsonModel229LeakageTester,standard equipment item No. 21641, RCA Model WT540A or use alternate method as follows : Plug the power cord directly
15、Into a 120 volt AC receptacle (do not use an Isolation Transformer for this test). Using two clip leads, connect a 1500ohms,10wattResistorparalleledbya0.15uFcapacitor,inserieswithallexposedmetalcabinetpartsandaknownearthground,such as a water pipe or conduit. Use a VTVM or VOM with 1000 ohms per vol
16、t, or higher sensitivity to measure the AC voltage drop across the resistor. (See diagram) Move the resistor connection to each exposed metal part having a return path to the chassis (antenna, metal, be performedwiththe0.35voltRMSormoreisexcessiveandindicatesapotentialshockhazardwhichmustbecorrected
17、beforereturningthe unittotheowner. - 5 - 300RadioFans.CN 收音机爱 好者资料库 ? RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 SERVICE PROCEDURE TEST EQUIPMENT REQUIRED 1) AM/FM Signal generator 2) Digital Multimeter 3) Distortion lever meter 2. VFD segment illumination CENTER MAIN: V
18、R401, VR402, VR501 SURROUND : VR601, VR602 2) NO signal / NO LOAD 3) AC LINE VOLTAGE : 120V/60Hz, 230V/50Hz (2) After turning on the unit, keep it over than 5MIN. (Keep the Power/Drive TR as normal temperature) (3) Adjust the voltage value of primary CENTER MAIN: VR403, VR404, VR502 SURROUND : VR603
19、, VR604 2) NO signal / NO LOAD 3) AC LINE VOLTAGE : 120V/60Hz, 230V/50Hz (2) After turning on the unit, keep it over than 5MIN. (Keep the Power/Drive TR as normal temperature) (3) Adjust the voltage value of primary cut any plastic cable ties necessary to fully disengage it 7) Lift and set the recei
20、ver on its right side for the remainder of the procedure. 8) Remove molex connector CN983 at the power switch; see Figure 1. 9) Pull the front panel as far away as the remaining connecting wires will allow. 10) Unsolder the connections at the rear of the front PCB to the volume encoder. 11) Using a
21、“stubby” Phillips screwdriver, remove the (19) Black Phillips screws holding the front PCB to the front panel; two plated screws at the rear of the headphone jack also must be removed. 12) Pull the front PCB away from the front panel. 13) Remove and replace the volume encoder with h/k part# J3261205
22、0102; resolder the new encoder in place. 14) Replace the front PCB and reassemble the receiver in reverse order, following the instructions above. Replace all cable ties that were cut, and reattach any connectors that were unplugged. Make sure the two ground wires on both sides of the receiver are r
23、eattached. 15) Power up receiver, and test volume control to assure it no longer changes settings by itself, or when the volume knob is tapped. RadioFans.CN 收音机爱 好者资料库 17 harman/kardon Incorporated 250 Crossways Park Drive, Woodbury New York 11797 (516) 496-3400 harman/kardon Service Bulletin Servic
24、e bulletin # H/K2000-02 Rev1 January 2001Warranty labor rate: MAJOR repair To: All harman/kardon Service Centers Models: AVR300, AVR500 Subject: Random Noise, Erratic Output in DTS Mode In the event you receive an AVR300 or AVR500 receiver with the complaint “there is distortion, random noise or gap