1、 harman/kardon AVR320 AVR320 A/V DOLBY DIGITAL RECEIVER SERVICE MANUAL CONTENTS ESD WARNING.2 LEAKAGE TESTING.3 BASIC SPECIFICATIONS.4 FRONT PANEL CONTROLS.5 REAR PANEL CONNECTIONS.10 REMOTE CONTROL FUNCTIONS.12 TROUBLESHOOTING GUIDE.15 PROCESSOR RESET.15 UNIT EXPLODED VIEW.16 EXPLODED VIEW PARTS LI
2、ST.17 BULLETIN H/K2002-03.19 BULLETIN H/K2002-07.20 BULLETIN H/K2003-07.21 TECH TIP HKTT2003-01.23 TECH TIP HKTT2004-03.24 IDLE CURRENT ADJUSTMENT.28 BLOCK DIAGRAM.31 ELECTRICAL PARTS LIST.32 SEMICONDUCTOR PINOUTS77 SCHEMATICS.136 WIRING DIAGRAM.157 PACKAGE.158 harman/kardon, Inc. 250 Crossways Park
3、 Dr. Woodbury, New York 11797 Rev5 6/2005 RadioFans.CN 收音机爱 好者资料库 Eachprecautioninthismanualshouldbefollowedduringservicing. Components identified with the IEC symbolin the parts list are special significance to safety. When replacing a component identified with , use only the replacement parts desi
4、gnated, or parts with the same ratings or resistance, wattage, or voltage that are designated in the parts list in this manual. Leakage-current or resistance measurements must be made to determine that exposed parts are acceptably insulated from the supply circuit before retuming the product to the
5、customer. Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field effect transistors and semiconductor chip components. Th
6、e following techniques should be used to help reduce the incidence of component damage caused by static electricity. 1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any electrostatic charge on your body by touching a known earth ground. Altern
7、atively, obtain and wear a commercially available discharging wrist strap device, which should be removed for potential shock reasons prior to applying power to the unit under test. 2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as
8、aluminum foil, to prevent electrostatic charge build-up or exposure of the assembly. 3. Use only a grounded-tip soldering iron to solder or unsolder ES devices. 4. Use only an anti-static solder removal device. Some solder removal devices not classified as anti-static can generate electrical charges
9、 sufficient to damage ES devices. 5. Do not use freon-propelled chemicals. These can generate electrical change sufficient to damage ES devices. 6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most replacement ES devices are
10、 packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable conductive material.) 7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material to the chassis or circuit assembly into which the d
11、evice will be installed. Be sure no power is applied to the chassis or circuit, and observe all other safety precautions. 8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the brushing together or your clothes fabric or the lifting of your
12、 foot from a carpeted floor can generate static electricity sufficient to damage an ES devices. CAUTION : AVR320 AVR320 harman/kardon harman/kardon RadioFans.CN 收音机爱 好者资料库 2 1. Inspect all lead dress to make certain that leads are not pinched or that hardware is not lodged between the chassis and ot
13、her metal partsintheunit. 2. Be sure that any protective devices such as nonmetallic control knobs, insulating fish- papers,cabinetbacks,adjustmentand compartment covers or shields, isolation resistor-capacitynetworks,mechanical insulators, etc. Which were removed for the servicingareproperlyre-inst
14、alled. Before returning the unit to the user, perform the following safety checks : 3. Be sure that no shock hazard exists ; check for leakage currentusingSimpsonModel229LeakageTester,standard equipment item No. 21641, RCA Model WT540A or use alternate method asfollows : Plug the power cord directly
15、 Into a 120 volt AC receptacle (do not use an Isolation Transformer for this test). Using two clip leads, connect a 1500ohms,10wattResistorparalleledbya0.15uFcapacitor,inserieswithallexposedmetalcabinetpartsandaknownearthground,such as a water pipe or conduit. Use a VTVM or VOM with 1000 ohms per vo
16、lt, or higher sensitivity to measure the AC voltage drop across the resistor. (See diagram) Move the resistor connection to each exposed metal part having a return path to the chassis (antenna, metal, cabinet,screwheads,knobsandcontrolshafts,escutcheon,etc.)andmeasuretheACvoltagedropacrosstheresisto
17、r.(Thistestshouldbe performedwiththe0.35voltRMSormoreisexcessiveandindicatesapotentialshockhazardwhichmustbecorrectedbeforereturningthe unittotheowner. AVR320 AVR320 harman/kardon harman/kardon RadioFans.CN 收音机爱 好者资料库 3 4 TECHNICAL SPECIFICATIONS Technical Specifications Audio Section Stereo Mode Co
18、ntinuous Average Power (FTC) 65 Watts per channel, 20Hz20kHz, 0.07% THD, both channels driven into 8 ohms Five-Channel Surround Modes Power Per Individual Channel Front L press it again to turn the unit off. Note that the Power Indicator 3 surrounding the switch will turn green when the unit is on.
19、3 Power Indicator: This LED will be lit in amber when the unit is in the Standby mode to signal that the unit is ready to be turned on. When the unit is in operation, the indicator will turn green. 4 Headphone Jack:This jack may be used to listen to the AVR 320s output through a pair of headphones.
20、Be certain that the headphones have a standard 1/4 stereo phone plug. Note that the main room speakers will automatically be turned off when the headphone jack is in use. 5 Dolby Mode Selector: Pressing this selec- tor button cycles the AVR through the various Dolby surround modes.The first press of
21、 the but- ton switches the surround mode to the last Dolby surround mode that was in use. Each sub- sequent press selects the next mode in the fol- lowing order: 6 DTS Surround Mode Selector: Pressing this selector button cycles the AVR through the DTS surround modes.The first press of the but- ton
22、selects the last DTS surround mode that DOLBY 3 STEREO DOLBY DIGITAL DOLBY PRO LOGIC II MUSIC DOLBY PRO LOGIC II MOVIES DOLBY PRO LOGIC II EMULATION Front Panel Controls 1 Main Power Switch 2 System Power Control 3 Power Indicator 4 Headphone Jack 5 Dolby Mode Selector 6 DTS Surround Mode Selector 7
23、 Logic 7 Mode Selector /Button 8 Tone Mode 9 Surround Mode Selector ) Tuning Selector ! Tuner Band Selector Set Button # Preset Station Selector $ Stereo Mode Selector /Button % Input Source Selector FM Mode Selector the tuner will automatically scan for the next station with an acceptable signal an
24、d then stop. ! Tuner Band Selector: Pressing this but- ton will automatically switch the AVR 320 to the Tuner mode. Pressing it again will switch between the AM and FM frequency bands. (See page 31 for more information on the tuner.) Set Button:When making choices during the setup and configuration