1、VM200 Service Manual Model DIGITAL RECORDING MIXER RadioFans.CN 收音机爱 好者资料库 SAFETY INSTRUCTIONS Read instructions - All the safety and operating instruc- tions should be read before the appliance is operated. Retain instructions - The safety and operating instructions should be retained for future re
2、ference. Heed warnings - All warnings on the appliance and in the operating instructions should be adhered to. Follow instructions - All operating and use instructions should be followed. Water and Moisture - The appliance should not be used near water - for example, near a bathtub, washbowl, kitche
3、n sink, laundry tub, in a wet basement, or near a swimming pool, and the like. Carts and Stands - The appliance should be used only with a cart or stand that is recommended by the manufac- turer. An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven su
4、rfaces may cause the appliance and cart combination to over- turn. Wall or Ceiling Mounting - The appliance should be mounted to a wall or ceiling only as recommended by the manufacturer. Ventilation - The appliance should be situated so that its location or position does not interfere with its prop
5、er ven- tilation. For example, the appliance should not be situ- ated on a bed, sofa, rug, or similar surface that may block the ventilation openings; or, placed in a built-in installa- tion, such as a bookcase or cabinet that may impede the flow of air through the ventilation openings. Heat - The a
6、ppliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat. Power Sources - The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on the
7、 appliance. Grounding or Polarization - The precautions that should be taken so that the grounding or polarization means of an appliance is not defeated. Power Cord Protection - Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against
8、 them, paying particular attention to cords at plugs, convenience recep- tacles, and the point where they exit from the appliance. Cleaning - The appliance should be cleaned only as rec- ommended by the manufacturer. Nonuse Periods - The power cord of the appliance should be unplugged from the outle
9、t when left unused for a long period of time. Object and Liquid Entry - Care should be taken so that objects do not fall and liquids are not spilled into the en- closure through openings. Damage requiring Service - The appliance should be ser- viced by qualified service personnel when: A. B. C. D. E
10、. Servicing - The user should not attempt to service the ap- pliance beyond that described in the operating instruc- tions. All other servicing should be referred to qualified service personnel. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO RE
11、DUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT. POUR VITER LES CHOCS LECTRIQUES, INTRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRE- SPONDANTE DE LA PRISE E
12、T POUSSER JUSQU AU FOND. CAUTION: ATTENTION: The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and mainte- nance (servicing) instructions in the literature accompanying the appliance. The lightening flash with arrowhead symbol,
13、within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the products en- closure that may be of sufficient magnitude to constitute a risk of electric shock to persons. “WARNING” “TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPO
14、SE THIS APPLIANCE TO RAIN OR MOIS- TURE.” 1. 2. 3. 4. 5. 6. 7. 8. The power supply cord or the plug has been damaged; or Objects have fallen, or liquid has been spilled into the appliance; or The appliance has been exposed to rain; or The appliance does not appear to operate normally or exhibits a m
15、arked changed in performance; or The appliance has been dropped, or the enclosure damaged. 9. 10. 11. 12. 13. 14. 15. 16. 17. RadioFans.CN 收音机爱 好者资料库 VM200 3 Parts marked with this sign are safety critical components. They must always be replaced with identical components. Refer to the Fostex Parts
16、List and ensure exact replacement. CAUTION TABLE OF CONTENTS 1. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. CONTROLS, INDICATORS & CONNECTORS . . . . . . . . . . . . 3. SOFTWARE UPDATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4. UTILITY MODE .
17、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5. EXPLODED VIEW, PCB ASSEMBLY & PARTS LIST . . . . . . 6. CIRCUIT DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Owners manual: 8288433100 (for export model) : 8288434100 (for domestic model) Owners manual supp
18、lement: 8288671000 (for export model) Service mode, error code list, exploded view, PCB assembly, parts list and circuit diagrams are given in this manual to assist the service technician in maintaining the Model VM200. NOTES The following accessories are supplied with VM200 as the standard accessor
19、ies.* * Following is the packing material for the Model VM200.* Carton, inner, VM200: 8228728000 Carton, outer, VM200: 8228907000 Packing, side, L, VM200: 8228453001 Packing, side, R, VM200: 8228453002 Sheet, power cable: 8228462000 4 6 8 9 12 33 RadioFans.CN 收音机爱 好者资料库 4 VM200 1. SPECIFICATIONS DEF
20、INITION Specification Unit0 dBV = 1 Vrms Standard Input (Impedance) MIC-60 dBV, -34 dBV (3 k or more) LINE-10 dBV (10 k or more) INSERT-10 dBV (20 k or more) 2TRACK IN-10 dBV (10 k or more) EFFECT RETURNAt 70 90 % position DATA OUT S/P DIF INIEC 60958 (S/P DIF) ADAT INAlesis Proprietary Multi Channe
21、l Digital Interface Standard Output (Impedance) STEREO-10 dBV (10 k load or more) MONITOR-10 dBV (10 k load or more) AUX-10 dBV (10 k load or more) REC BUSS-10 dBV (10 k load or more) HEADPHONE50 mW or more (33 load) STANDARD FADER POSITION STEREO BUSSSet the INPUT / MASTER faders at “0” position wh
22、en -10 dBV / 1 kHz signal is fed to the INPUT (INSERT) jack (TRIM: MIN, PAN: L (R), EQ: OFF). MONITORSet the MONITOR VR so that -10 dBV output is obtained at MONITOR OUT when -10 dBV / 1 kHz signal is fed to the INPUT (INSERT) jack. OUTPUT LEVEL INPUT (1 8) STEREO-10 dBV +2, -1 dB (Standard fader po
23、sition) INPUT (1 8) MONITOR-10 dBV +2, -1 dB (Standard fader position) FREQUENCY RESPONSE INPUT MONITOR OUT Input: -60 dBV20 20 kHz +1, -3 dB Input: -10 dBV20 20 kHz +1, -3 dB INPUT STEREO OUT Output: -10 dBV20 20 kHz +1, -3 dB INPUT PHONES Output: 50 mW / 33 50 20 kHz +1, -3 dB EQUALIZER HI / HI MI
24、D / LOW MID / LOW +18+18 dB 3 dB -18-18 dB 3 dB S/N Residual Noise AUX 1 4 ST BUSS OUT-88 dBV or less (All input / master faders: MIN) -75 dBV or less (All input / master faders: At 0 dB) MIC INSERT-68 dBV or less (GAIN: MAX, PAD: OFF, Rs: 150) MONITOR OUT (VR: MIN)-100 dBV or less PHONES-95 dBV or