1、D&M Holdings Inc. SERVICE MANUAL e e Copyright 2010 D&M Holdings Inc. All rights reserved. WARNING: Violators will be prosecuted to the maximum extent possible. MODELJPE3E2EKEAE1E1KE1C PMA-A100? INTEGRATED AMPLIFIER Ver. 3 Some illustrations using in this service manual are slightly different from t
2、he actual set. Please use this service manual with referring to the operating instructions without fail. For purposes of improvement, specif cations and design are subject to change without notice. S0226-1V03DM/DG1012 Please refer to the MODIFICATION NOTICE. RadioFans.CN 收音机爱 好者资料库 2 SAFETY PRECAUTI
3、ONS The following check should be performed for the continued protection of the customer and service technician. LEAKAGE CURRENT CHECK Before returning the unit to the customer, make sure you make either (1) a leakage current check or (2) a line to chassis resistance check. if the leakage current ex
4、ceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the unit is defective. Be sure to test for leakage current with the AC plug in both polarities, in addition, in each power ON, OFF and STANDBY mode, if applicable. CAUTION Please heed the
5、points listed below during servicing and inspection. Heed the cautions! Spots requiring particular attention when servicing, such as the cabinet, parts, chassis,etc., have cautions indicated on labels. be sure to heed these causions and the cautions indicated in the handling instructions. Caution co
6、ncerning electric shock! (1) An AC voltage is impressed on this set, so touching internal metal parts when the set is energized could cause electric shock. Take care to avoid electric shock, by for example using an isolating transformer and gloves when servicing while the set is energized, unpluggin
7、g the power cord when replacing parts, etc. (2) Tere are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly! Through great care is taken when manufacturing parts from sheet metal, there may in some rare cases be burrs on the edges
8、 of parts which could cause injury if fi ngers are moved across them. Use gloves to protect your hands. Only use designated parts! The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). For replacement parts, be sure to use parts which have the same poroperties.
9、In particular, for the important safety parts that are marked z on wiring diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were originally! For safety seasons, some parts use tape, tubes or other insulating materials, and some parts
10、are mounted away from the surface of printed circuit boards. Care is also taken with the positions of the wores omsode amd clamps are used to keep wires away from heating and high voltage parts, so be sure to set everything back as it was originally. Inspect for safety after servicing! Check that al
11、l screws, parts and wires removed or disconnected for servicing have been put back in their original positions, inspect that no parts around the area that has been serviced have been negatively affected, conduct an inslation check on the external metal connectors and between the blades of the power
12、plug, and otherwise check that safety is ensured. (Insulation check procedure) Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and turn the power switch on. Using a 500V insulation resistance tester, check that the inplug and the externally exposed metal parts (ante
13、nna terminal, headphones terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired. Many of the electric and structural parts used in the set have special safety properties. In most cases these properties are difficult to distinguish by sight, and using
14、replacement parts with higher ratings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be poreserved. Parts with safety properties are indicated as shown below on the wiring diagrams and parts lists is this service manual. Be sure to replace them with p
15、arts with the designated part number. (1) Schematic diagrams .Indicated by the z mark. (2) Parts lists .Indicated by the z mark. Using parts other than the designated parts could result in electric shock, fi res or other dangerous situations. CAUTION Concerning important safety parts RadioFans.CN 收音
16、机爱 好者资料库 3 DIMENSION 60 434 20161 2639435 MAX 332 344 7026163 4 WIRE ARRANGEMENT If wire bundles are untied or moved to perform adjustment or parts replacement etc.,be sure to rearrange them neatly as they were originally bundled or placed afterward. Otherwise, incorrect arrangement can be a cause o
17、f noise generation. The photograph is PMA-2010AE. Wire arrangement viewed from the top Front Panel side Back Panel side 5 Wire arrangement viewed from the bottom Front Panel side Back Panel side 6 DISASSEMBLY Disassemble in order of the arrow of the figure of following flow. In the case of the re-as
18、sembling, assemble it in order of the reverse of the following flow. In the case of the re-assembling, observe attention of assembling it. TOP COVER SIDE COVER (L)SIDE COVER (R)P.AMP(R) UNIT Refer to DISASSEMBLY 3.P.AMP(R) UNIT and EXPLODED VIEW P.AMP(L) UNITINPUT UNIT and PH/CD TER.UNITP.AMP(R) UNI
19、T Refer to DISASSEMBLY 1.P.AMP(R) UNITRefer to DISASSEMBLY 2.INPUT UNIT (Ref. No. of EXPLODED VIEW : 3-2) and EXPLODED VIEWand PH/CD TER.UNIT and EXPLODED VIEWMULTIPLIER UNIT P.AMP(L) UNITINPUT UNIT (Ref. No. of EXPLODED VIEW : 3-4) (Ref. No. of EXPLODED VIEW : 3-1) (Ref. No. of EXPLODED VIEW : 1-1)
20、 MULTIPLIER UNITPH/CD TER.UNIT (Ref. No. of EXPLODED VIEW : 3-3) (Ref. No. of EXPLODED VIEW : 3-7)CONECT UNIT Refer to EXPLODED VIEW CONECT UNIT FRONT PANEL ASSYBOTTOM COVER (Ref. No. of EXPLODED VIEW : 1-8) Refer to DISASSEMBLY 4.FRONT PANEL ASSYRefer to DISASSEMBLY 5.BOTTOM COVER and EXPLODED VIEW
21、and EXPLODED VIEW DIRECT SW UNITDIODE UNITAC UNIT (Ref. No. of EXPLODED VIEW : 1-2) (Ref. No. of EXPLODED VIEW : 1-7)Refer to EXPLODED VIEW MAIN VR UNITCONTROL UNITAC UNIT (Ref. No. of EXPLODED VIEW : 1-3) (Ref. No. of EXPLODED VIEW : 2) (Ref. No. of EXPLODED VIEW : 1-9) F SW UNIT (Ref. No. of EXPLO
22、DED VIEW : 1-4)CE33W=123M REC OUT SEL. SW UNITRefer to DISASSEMBLY 8.CE33W=123MREC OUT UNIT (Ref. No. of EXPLODED VIEW : 1-5)and EXPLODED VIEWRefer to EXPLODED VIEW P DIRECT SW UNITREC OUT UNIT (Ref. No. of EXPLODED VIEW : 1-6) (Ref. No. of EXPLODED VIEW : 3-8) P SWITCH UNIT (Ref. No. of EXPLODED VI
23、EW : 1-10) P LED UNITSP TERMINAL UNIT (Ref. No. of EXPLODED VIEW : 1-11)Refer to EXPLODED VIEW TONE UNITSP TERMINAL UNIT (L-ch) (Ref. No. of EXPLODED VIEW : 3-5) (Ref. No. of EXPLODED VIEW : 95-1) H/P UNITSP TERMINAL UNIT (R-ch) (Ref. No. of EXPLODED VIEW : 3-6) (Ref. No. of EXPLODED VIEW : 95-2) FL
24、AT AMP UNIT and POWER SUPPLY UNIT Refer to EXPLODED VIEW FLAT AMP UNIT (Ref. No. of EXPLODED VIEW : 4-1) POWER SUPPLY UNIT (Ref. No. of EXPLODED VIEW : 4-2) 7 About the photos used for descriptions in the “DISASSEMBLY” section. The direction from which the photographs used herein were photographed i