Classe-CA150-pwr-sm维修电路原理图.pdf
《Classe-CA150-pwr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Classe-CA150-pwr-sm维修电路原理图.pdf(22页珍藏版)》请在收音机爱好者资料库上搜索。
1、PRO-SVR_LEGACY Page 1 of 14 Date: August 14, 2007 Model Number: CA-150-151 Class Audio Inc. Subject: Service manual Class Audio, Inc. 5070 Franois Cusson Lachine, Qubec Canada H8T1B3, RadioFans.CN 收音机爱 好者资料库 PRO-SVR_LEGACY Page 2 of 14 Table of Contents Introduction 3 Important Notes on Servicing 3
2、Ordering Replacement Parts 3 Block Diagrams 4 Start up Procedure 5 Protection Modes and Indicators 6 Troubleshooting Guide 7 Output Transistors Testing and Replacement 8 Calibrations and Adjustments 9 Parts List 10 Updates 11 Fuses 13 Voltage Change 13 Remote Interface Information 14 Schematics 15 T
3、he contents of this document as well as the files associated with it contain confidential information that is proprietary to Class Audio Incorporated and are intended solely for the purpose of servicing product. No part of its contents may be used, copied, disclosed, or conveyed to any party in any
4、manner whatsoever without prior written permission from Class Audio Incorporated. RadioFans.CN 收音机爱 好者资料库 PRO-SVR_LEGACY Page 3 of 14 Introduction Please read this manual carefully before commencing servicing! Only qualified and authorized personnel should attempt to service this product. The lightn
5、ing flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated dangerous voltage within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilat
6、eral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions. Class has a global product support network. For product assistance or to order replacement parts please contact your nearest service center always quoting the unit serial numb
7、er. North America Phone: (978) 664-2870 E-mail: Europe Phone: 44 (0) 1903 221 700 E-mail: Asia Phone: (852) 2790 8903 E-mail: classebwgroup.hk Rest of the World Phone: (514) 636-6384 E-mail: Important Notes on Servicing 1.ALWAYS observe ESD precautions when handling electronic modules or PCBAs. 2.NE
8、VER exchange boards with a different revision number, unless authorized by Class. 3.ALWAYS use Class original replacement parts. The use of generic parts may void the warranty of the unit. Ordering Replacement Parts There may be a delay in processing incomplete requests. Please be sure to include al
9、l required information. Remember to quote the serial number of the unit on all replacement part orders and the Class order number when returning defective parts for credit. PRO-SVR_LEGACY Page 4 of 14 Block diagrams PRO-SVR_LEGACY Page 5 of 14 Start Up Procedure When receiving a unit, an assiduous v
10、isual inspection must be performed. Do not connect the unit without analysing the symptoms reported by the customer and the results of the inspection. Using the troubleshooting guide, find the problem and proceed to the repair. Once this step is done, follow these steps, known as the start-up proced
11、ure, to ensure that everything in the unit is in working condition. 1. Proceed with a post repair visual inspection. Take the time to check if every wire is reconnected properly, every screw is bolted on, no soldering and/or metal residues lying in the unit, every fuse has been replaced, etc. 2. Con
12、nect the unit to a variable transformer, setted to 0Vac. 3. Turn the bias trimpot (RV102) counter clockwise until a click is heard. 4. Connect the bypass wire to the variable transformer. This bypass is a power cord, modified on the female side in order to bypass the soft start sequence. It is conne
13、cted to the line ring on voltage selector PCB. 5. Slowly raise the voltage to 10Vac, and check positive and negative rails and pre-driver supply. Check fuses. 6. If one or more supply are not within specifications, return to the troubleshooting guide. 7. Slowly raise voltage until you hear relays cl
14、ick, this point is around 55Vac. Recheck every supply. 8. If one or more supply are not within specifications, return to the troubleshooting guide. 9. Raise voltage to 120Vac. Recheck every supply 10. If every supply is within specifications, unplug the unit and bypass from the variable transformer.
15、 Reconnect only the unit. 11. Report to Calibration and adjusments (section 9) to adjust bias and DC offset. Note that bias can be adjusted to 14mV, and the following tests can be performed before the unit is send to the burn-in bench for a 24 hours warm-up. 12. Connect the unit to a load, and to a
16、source using balanced inputs and single ended inputs, independently. 13. Perform a test with a 200Hz, a 2kHz and a 20kHz tone, both sinus wave and square wave. Check the output with a oscilloscope, on 4 ohms and 8 ohms loads. Take special cares about oscillation and phase correlation between channel
17、s. 14. Connect the unit to a small speaker, and short the input. Check for any noise. Perform this step with single ended inputs and balanced inputs, independently. 15. Put the unit on a burn-in bench, and let it sit for 24 hours, then readjust bias. Let the unit on the burn- in bench for another 72
18、 hours. 16. Redo steps 11 to 14 before shipping to the customer. PRO-SVR_LEGACY Page 6 of 14 Protection Modes and Indicators The front LED shows the status of the amplifier. When starting up normally, the CA150 and CA151 will show a FLASHING RED LED for about 15 seconds and if all is normal, the LED
19、 will go SOLID RED. If there is a fault, the LED will go to a FLASHING GREEN LED. The CA150 and CA151 are equipped, except for some early production models, with four rails protection fuses. In the event that one or more of these fuses would blow, the technician will first need to identify and cure
20、the cause of failure (please report to troubleshooting guide). When the cause has been identified, disconnect the unit from the system including the AC power. Remove the top cover and look for damaged or burned components. If no other components than the fuses appear to be damaged, the technician ca
21、n then replace the broken fuses with the same value and rating (please report to fuses section). The rail fuses are located on the capacitor board. When replacing fuses, please make sure that the fuse holder are holding the fuses very tightly. A loose fuse holder can translate into distortion on top
22、 of the signal. PRO-SVR_LEGACY Page 7 of 14 Troubleshooting Guide Symptom Possible cause Unit won t turn on Check connections; Check fuses; Check soft-start circuit; Check relays; Check power supply circuits (positive rail, negative rail, Mosfet supply). Smoked and/or burned components Check for sho
23、rt between components and ground; Check output transistors; Check output relays; Check power supply circuits (positive rail, negative rail, Mosfet supply). Blown fuses Check for short between fuse and ground; Check power supply circuits (positive rail, negative rail, Mosfet supply). No output Check
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Classe CA150 pwr sm 维修 电路 原理图