1、BeoLab 3500 MKII Type1601,1602,1603,1604,1605,1607,1608 fromserialno.19343452 ServiceManual English German and French, versions are available in the Retail System ABO-CENTER v/HENRIKSENS ELEKTRONIK RadioFans.CN 收音机爱 好者资料库 CONTENTS Survey of modules . 1.1 Adjustments . 2.1 Repair tips . 3.1 Disassemb
2、ly . 4.1 Insulation test . 5.1 Specification guidelines for service use . 6.1 Wiring diagram . 7.1 Block diagrams . 7.3 7.5 Available parts . 8.1 ABO-CENTER v/HENRIKSENS ELEKTRONIK RadioFans.CN 收音机爱 好者资料库 Survey of modules 1.1 2 Switch Mode Power Supply 19 DC/DC Converter 20 Transformer left 21 Tran
3、sformer right 22 Power Amplifier left 22 Power Amplifier right 25 NTC 31 LF Supply and Control 32 Cross Field 34 Plug PCB 35 Display, Keyboard and IR Receiver 36 Microcomputer Seen from the front 36 34 20222 25 3235 21 19 31 22 25 Seen from the back ABO-CENTER v/HENRIKSENS ELEKTRONIK 1. ABO-CENTER v
4、/HENRIKSENS ELEKTRONIK Adjustments 2. ADJUSTMENTS 5V When replacing IC, LM3578, on PCB2, Switch-Mode Power Supply, the supply voltage may have to be adjusted to 5V 0.25V by means of R2 and R0: - If 5V is above level, install R2 (R/R2). - If 5V is below level, install R0 (R3/R0). SPEAKER Adjustment o
5、f bass/treble sound level. To be carried out only when replacing a speaker unit or PCB36, Microcomputer. TEST MODE 0 This test mode permits manual adjustment of speaker bass and treble levels and can only be executed from stand-by with a Beo4. - Press MENU 0 1 GO. The display reads SPK.CAL. to indic
6、ate that the product is ready for speaker calibration. - Press GO. The display shows the present adjustment: X X X X = left bass (LB). X X X X = left treble (LT). X X X X = right treble (RT). X X X X = right bass (RB). The value that can be changed is flashing. Press or to select speaker, if necessa
7、ry (the active speaker is flashing), and enter a new digit (see table). Negative: If the rated value printed on the back of the speaker is negative, the other three units must be damped by X number of steps. Press to select the three speakers in question, and enter new digits (see table). Rated valu
8、e in dB X steps down 0.00 +/-0.25 0 steps down +/-0.50 +/-0.75 +/-.00 +/-.25 step down +/-.50 +/-.75 +/-2.00 2 steps down - Press STORE when all four speakers have the desired encoding. - Abandon test mode by pressing STOP. ABO-CENTER v/HENRIKSENS ELEKTRONIK Repair tips 3. REPAIR TIPS BeoLab 3500 ca
9、n be brought into TEST MODE from stand-by with a Beo4, giving access to the following functions: TEST MODE 00 Display of: Software version number and time of operation in Audio mode, Video mode and stand-by. - Press MENU 0 0 GO. The display reads: SW X.Y, which is the software version number. - Pres
10、s m The display reads: A: XXXXX, which is the Audio mode operating time in hours x 0. - Press m The display reads: B: XXXXX, which is the Video mode operating time in hours x 0. - Press m The display reads: C: XXXXX, which is the stand-by operating time in hours x 0. Press m or p to scroll in the sc
11、roll menu, and abandon test mode by pressing STOP. TEST MODE 01 Electronic adjustment of the bass and treble levels of the speakers. See section 2, Adjustments. SERVICE SET-UP BeoLab 3500 is connected to a Beomaster as an ordinary Master link installation. As regards option programming, see Users Gu
12、ide. TEST MODE 02 Display of Master Link error types. Gives an identification of the error types that may occur in the Beolink installation. - Press MENU 0 2 GO The display reads: ML OK = The Master Link connection is OK. Or NO ML = Master Link is not connected. Or ERROR = Address configuration impo
13、ssible. Or ERROR 2 = Master Link data pulled low. Or ERROR 3 = Master Link data pulled high. Or ERROR 4 = Data collision on Master Link. - Press STOP to abandon display of Master Link error types and to delete registered errors. The Master Link error system is a part of the software in the product.
14、It registers communication errors between the microcomputer, the data transceiver circuits (PCB35) and the products connected to BeoLink. The error types will be described below, and tips will be given regarding how the cause of the error can be found: ABO-CENTER v/HENRIKSENS ELEKTRONIK 3.2 Repair t
15、ips ERROR : Error during address configuration. No address has been allocated because too many units are connected to the BeoLink. - Remove all products from BeoLink, and connect them again one at a time until the error code occurs. Disconnect that product from BeoLink. ERROR 2: It is not possible t
16、o transmit on BeoLink, because it has been pulled low. The error may occur if there is no Master Link driver circuit, or as a result of a physical short- circuit on BeoLink or in the data transceiver circuits. - Disconnect one product from BeoLink at a time, and see if it starts up. - Reset the faul
17、ty product, and check the connection (cable/plug) and signal path (the data transceiver circuits). ERROR 3: It is not possible to transmit on BeoLink, because it has been pulled high. This error is caused either by the pull-up resistance in the system having become too small or by an error in the da
18、ta transceiver circuit. - Disconnect one product from BeoLink at a time, and see if it starts up. - Reset the faulty product, check whether the Master Link cable is too long, and check the signal path (the data transceiver circuit). ERROR 4: The data traffic on BeoLink has been excessive, or a produ
19、ct has jammed and will not receive telegrams. - Press the operating sequence again. - Disconnect one product from BeoLink at a time to determine which product has jammed. Reset the faulty product, and check the Master Link connection (cable/ plug) and signal path (amplifiers in the data transceiver
20、circuit). TEST MODE 0 3 Direct selection of Master Link input. Permits the Master Link signal path to be tested without having a BeoLink master connected. - Press MENU 0 3 GO The display reads: ML SEL. = Opens the Master Link signal path. - Press STOP to close the Master Link signal path. ABO-CENTER
21、 v/HENRIKSENS ELEKTRONIK Disassembly 4. DISASSEMBLY Front fabric frame - Push the front fabric frame to the side and lift it off. When both front fabric frames have been removed, PCB35, Display, Keyboard & IR receiver, PCB36, Microcomputer, and PCB32, Cross field, are accessible: - Remove the displa
22、y glass (two screws) and the two plastic covers (four screws). PCB35 can now be tilted out into service position, thereby also providing access to PCB36 and PCB32. 35 32 36 ABO-CENTER v/HENRIKSENS ELEKTRONIK 4.2 Disassembly Service position Important! The display glass and cabinet must be protected
23、against scratches by placing them on a soft base. - Remove the sixteen screws, A, behind the front fabric frames. - Place the front face down. - Remove the socket well by first removing the two Allen screws. - Lift the cabinet up and off carefully. Place the cabinet parallel to the electronics block