Yamaha-DM-2000-E-Service-Manual-part-3电路原理图.pdf
201 DM2000 data item. Effect is 0:Effect 17:Effect 8, GEQ is 0:GEQ15:GEQ6 If the store destination is 16383 (0 x3FFF), this indicates that the library data has been changed by a external cause (i.e., loading from SmartMedia) (only transmitted by the DM2000) *2) This is also transmitted when a program that has not been assigned to the Program change table is recalled. (Normally this would be transmitted as a program change message.) 12.3.15 Parameter change (Function call: title) Reception This is received if Parameter change RX is ON and the Rx CH matches the device number included in the SUB STATUS. This is echoed if Parameter change ECHO is ON. When this is received, the title of the specified memory/library will be changed Transmission In response to a request, a Parameter Change message will be transmitted on the Rx CH. If Parameter change ECHO is ON, this message will be retransmitted without change. 12.3.16 Parameter request (Function call: title) Reception This is received if Parameter change RX is ON and the Rx CH matches the device number included in the SUB STATUS. This is echoed if Parameter change ECHO is ON. When this is received, a Parameter Change message will be transmitted on the Rx CH. Refer to the above table for the Functions and Numbers. 12.3.17 Parameter change (Function call: Scene/Library Clear) Reception This is received if Parameter change RX is ON and the Rx CH matches the device number included in the SUB STATUS. This is echoed if Parameter change ECHO is ON. When this is received, the specified memory/library will be stored/recalled. Transmission If Parameter change ECHO is ON, this message will be retransmitted without change. 12.3.18 Parameter change (Function call: pair, copy) Reception This is received if Parameter change RX is ON and the Rx CH matches the device number included in the SUB STATUS. This is echoed if Param- eter change ECHO is ON. When this is received, pairing will be enabled/disabled for the specified channel. (Items other than PAIR are reserved for future use.) *1)0:CH1 - 95:CH96, 128:BUS1 - 135:BUS8, 256:AUX1 - 267:AUX12, 384:MATRIX1L - 391:MATRIX4R, 512:STE- REO L - 513:STEREO R Effect is 0:Effect 17:Effect 8, GEQ is 0:GEQ15:GEQ6 In the case of PAIR, you must specify channels for which pair- ing is possible. In the case of PAIR ON with COPY, you must specify Source Channel as the copy source, and Destination Channel as the copy destination. 12.3.19 Parameter change (Function call Event: Effect) Reception This is received if Parameter change RX is ON and the Rx CH matches the device number included in the SUB STATUS. This is echoed if Parameter change ECHO is ON. STATUS11110000 F0System exclusive message ID No.01000011 43Manufactures ID number (YAMAHA) SUB STATUS0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID00111110 3EMODEL ID (digital mixer) MODEL ID00000110 7FUniversal ADDRESS00010000 10Function call Library 0100aaaa 4aAddress UL (function) 0nnnnnnn nnAddress LU (number H) 0nnnnnnn nnAddress LL (number L) DATA 0ddddddd ddtitle 1 : 0ddddddd ddtitle x(depend on the library) EOX11110111 F7End of exclusive functionnumbersize SCENE LIB TITLE0 x400-99, 256(0:response only) 16 EQ LIB TITLE0 x411-200(1-40:response only)16 GATE LIB TITLE0 x421-128(1-4:response only)16 COMP LIB TITLE0 x431-128(1-36:response only)16 EFF LIB TITLE0 x441-128(1-52:response only)16 GEQ LIB TITLE0 x450-128(0:response only)16 CHANNEL LIB TITLE0 x460-128(0-1:response only)16 INPATCH LIB TITLE0 x470-32(0:response only)16 OUTPATCH LIB TITLE0 x480-32(0:response only)16 Bus to Stereo LIB TITLE0 x490-32(0:response only)16 Surround Monitor LIB TITLE0 x4A0-32(0:response only)16 AUTOMIX LIB TITLE0 x4B1-1616 STATUS11110000 F0System exclusive message ID No.01000011 43Manufactures ID number (YAMAHA) SUB STATUS0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID00111110 3EMODEL ID (digital mixer) MODEL ID00000110 7FUniversal ADDRESS00010000 10Function call Library 0100aaaa 4aAddress UL (function) 0nnnnnnn nnAddress LU (number H) 0nnnnnnn nnAddress LL (number L) EOX11110111 F7End of exclusive STATUS11110000 F0System exclusive message ID No.01000011 43Manufactures ID number (YAMAHA) SUB STATUS0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID00111110 3EMODEL ID (digital mixer) MODEL ID00000110 7FUniversal ADDRESS00010000 10Function call Library 0110aaaa 6aAddress UL (function) 0nnnnnnn nnAddress LU (number H) 0nnnnnnn nnAddress LL (number L) EOX11110111 F7End of exclusive functionnumber SCENE LIB CLEAR0 x601-99 EQ LIB CLEAR0 x6141-200 GATE LIB CLEAR0 x625-128 COMP LIB CLEAR0 x6337-128 EFF LIB CLEAR0 x641-128 GEQ LIB CLEAR0 x650-128 CHANNEL LIB CLEAR0 x662-128 INPATCH LIB CLEAR0 x670-32 OUTPATCH LIB CLEAR0 x680-32 Bus to Stereo LIB CLEAR0 x690-32 Surround Monitor LIB CLEAR0 x6A0-32 AUTOMIX LIB CLEAR0 x6B1-16 STATUS11110000 F0System exclusive message ID No.01000011 43Manufactures ID number (YAMAHA) SUB STATUS0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID00111110 3EMODEL ID (digital mixer) MODEL ID00000110 7FUniversal ADDRESS00010001 11Function call Pair 0000aaaa 0aFunction DATA 0ddddddd ddSource channel number H 0ddddddd ddSource channel number L 0ddddddd ddDestination channel number H 0ddddddd ddDestination channel number L EOX11110111 F7End of exclusive functionChannel PAIR ON with COPY0 x00*1) PAIR ON with RESET BOTH0 x01*1) PAIR OFF0 x02*1) RadioFans.CN 收音机爱 好者资料库 DM2000 202 When this is received, the corresponding effects function activates (de- pending on the effect type). This does not activate when the effect type is different. 12.3.20 Parameter change (Key remote) Reception This is received if Parameter change RX is ON and the Rx CH matches the device number included in the SUB STATUS. This is echoed if Parameter change ECHO is ON. When this is received, the same processing that is executed when the key specified by Address is pressed (released). (Refer to the PARAMETER CHANGE PARAMETER NUMBER LIST.) Transmission If Parameter Change ECHO is ON, this message is retransmitted without change. 12.3.21 Parameter change (Remote Meter) When transmission is enabled by receiving a Request of Remote meter, the specified meter information is transmitted every 50 msec for 10 seconds. When you want to transmit meter information continuously, a Request must be transmitted continuously within every 10 seconds. Reception This is echoed if Parameter change ECHO is ON. Transmission When transmission has been enabled by a Request, the parameter specified by Address (see PARAMETER CHANGE PARAMETER NUMBER LIST) will be transmitted on the Rx CH channel at 50 msec intervals for a du- ration of 10 seconds. Transmission will be disabled if the power is turned off and on again, or if the PORT setting is changed. If Parameter Change ECHO is ON, this message is retransmitted without change. Meter data uses the unmodified DECAY value of the DSP. For the inter- pretation of the value, refer to the PARAMETER CHANGE PARAMETER NUMBER LIST. 12.3.22 Parameter request (Remote Meter) Reception This is received if Parameter change RX is ON and the Rx CH matches the device number included in the SUB STATUS. This is echoed if Parameter change ECHO is ON. When this is received, the parameter specified by Address (refer to PA- RAMETER CHANGE PARAMETER NUMBER LIST) will be transmitted on the Rx CH at 50 msec intervals for a duration of 10 seconds. If Address UL= 0 x7F is received, transmission of all meter data will be halt- ed immediately. (disable) Transmission If Parameter Change ECHO is ON, this message is retransmitted without change. 12.3.23 Parameter change (Remote Time Counter) When transmission is enabled by receiving a Request of Remote Time Counter, the Time Counter data is transmitted every 50 msec for 10 sec- onds. When you want to transmit Counter information continuously, a Request must be transmitted within every 10 seconds. Reception This is echoed if Parameter change ECHO is ON. Transmission When transmission is enabled by receiving a Request, the Time Counter information is transmitted on RxCH channel every 50 msec for 10 sec- onds. Transmission will be disabled if the power is turned off and on again, or if the PORT setting is changed. If Parameter Change ECHO is ON, this message is retransmitted without change. 12.3.24 Parameter request (Remote Time Counter) Reception This is received if Parameter change RX is ON and the Rx CH matches the device number included in the SUB STATUS. This is echoed if Parameter change ECHO is ON. When this is received, the Time Counter information is transmitted on the Rx CH channel every 50 msec for 10 seconds. When the second byte of Address is received on 0 x7F, data transmission will be halted immediately. Transmission If Parameter Change ECHO is ON, this message is retransmitted without STATUS11110000 F0System exclusive message ID No.01000011 43Manufactures ID number (YAMAHA) SUB STATUS0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID00111110 3EMODEL ID (digital mixer) MODEL ID00000110 7FUniversal ADDRESS00010010 12Function call Event 0000aaaa 0aFunction DATA 00000000 00- 0ddddddd ddRelease:0, Press:1 00000000 00- 0ddddddd ddDestination Effect Number 0 - 7 EOX11110111 F7End of exclusive functionChannel Freeze Play button0 x000:Effect1-7:Effect8 Freeze Record button0 x010:Effect1-7:Effect8 Auto Pan 5.1 Trigger Button0 x020:Effect1-1:Effect2 Auto Pan 5.1 Reset Button0 x030:Effect1-1:Effect2 STATUS11110000 F0System exclusive message ID No.01000011 43Manufactures ID number (YAMAHA) SUB STATUS0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID00111110 3EMODEL ID (digital mixer) MODEL ID00000110 06DM2000 ADDRESS00100000 20Address UU 0aaaaaaa aaAddress UL 0aaaaaaa aaAddress LU 0aaaaaaa aaAddress LL DATA 0ddddddd dd0:press, 1:release EOX11110111 F7End of exclusive STATUS11110000 F0System exclusive message ID No.01000011 43Manufactures ID number (YAMAHA) SUB STATUS0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID00111110 3EMODEL ID (digital mixer) MODEL ID00000110 06DM2000 ADDRESS00100001 21Address UU 0aaaaaaa aaAddress UL 0aaaaaaa aaAddress LU 0aaaaaaa aaAddress LL DATA 0ddddddd ddData1 H 0ddddddd ddData1 L : EOX11110111 F7End of exclusive STATUS11110000 F0System exclusive message ID No.01000011 43Manufactures ID number (YAMAHA) SUB STATUS0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID00111110 3EMODEL ID (digital mixer) MODEL ID00000110 06DM2000 ADDRESS00100001 21Address UU 0aaaaaaa aaAddress UL 0aaaaaaa aaAddress LU 0aaaaaaa aaAddress LL DATA0ccccccccccCount H 0ccccccccCcCount L EOX11110111 F7End of exclusive STATUS11110000 F0System exclusive message ID No.01000011 43Manufactures ID number (YAMAHA) SUB STATUS0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID00111110 3EMODEL ID (digital mixer) MODEL ID00000110 06DM2000 ADDRESS00100001 22Remote Time Counter 0000tttt 0t0:Time Code, 1: Measure, Beat, Clock DATA 0ddddddd ddHour / Measure H 0ddddddd ddMin / Measure L 0ddddddd ddSec / Beat 0ddddddd ddFrame / Clock EOX11110111 F7End of exclusive RadioFans.CN 收音机爱 好者资料库 203 DM2000 change. 12.3.25 Parameter change (Automix Status) When transmission is enabled by receiving a Request of Automix status, the Automix Status data is transmitted every second for 10 seconds. When you want to transmit the Automix Status information continuously, the Request must be transmitted continuously minimum within 10 seconds interval. The data is transmitted continuously while the transmission is en- abled, even when the Automix Status on the DM2000 has been changed. Reception This is echoed if Parameter change ECHO is ON. Transmission When the transmission is set to enable by receiving a Request. The Auto- mix Status data is transmitted on the Rx CH channel every second for 10 seconds. The data is transmitted continuously while the transmission is enabled, even when the Automix Status on the DM2000 has been changed. Transmission will be disabled if the power is turned off and on again, or if the PORT setting is changed. If Parameter Change ECHO is ON, this message is retransmitted without change. 12.3.26 Parameter request (Automix Status) Reception This is received if Parameter change RX is ON and the Rx CH matches the device number included in the SUB STATUS. This is echoed if Parameter change ECHO is ON. When the data is received, the Automix Status data is transmitted on the Rx CH every second for 10 seconds. When the second byte of Address is received on 0 x7F, data transmission will be halted immediately (disable). Transmission If Parameter Change ECHO is ON, this message is retransmitted without change. STATUS11110000 F0System exclusive message ID No.01000011 43Manufactures ID number (YAMAHA) SUB STATUS0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID00111110 3EMODEL ID (digital mixer) MODEL ID00000110 06DM2000 ADDRESS00100001 22Remote Time Counter 0aaaaaaa aa0:Transmission request, 0 x7F:Transmission stop request EOX11110111 F7End of exclusive STATUS11110000 F0System exclusive message ID No.01000011 43Manufactures ID number (YAMAHA) SUB STATUS0001nnnn 1nn=0-15 (Device number=MIDI Channel) GROUP ID00111110 3EMODEL ID (digital mixer) MODEL ID00000110 06DM2000 ADDRESS00100011 23Automix Status 00000000 00 DATA 0000dddd 0dAutomix Status H 0000dddd 0dAutomix Status L EOX11110111 F7End of exclusive STATUS11110000 F0System exclusive message ID No.01000011 43Manufactures ID number (YAMAHA) SUB STATUS0011nnnn 3nn=0-15 (Device number=MIDI Channel) GROUP ID00111110 3EMODEL ID (digital mixer) MODEL ID00000110 06DM2000 ADDRESS00100011 23Automix Status 0aaaaaaa aa0:Transmission request, 0 x7F:Transmission stop request EOX11110111 F7End of exclusive 204 YAMAHA Digital Mixing Console-Internal ParametersDate: Feb 01, 2002 Model: DM2000MIDI Implementation ChartVersion: 1.0 Function.TransmittedRecognizedRemarks Basic Channel Default Changed 116 116 116 116 Memorized Mode Default Messages Altered X X * OMNI off/OMNI on X X Memorized Note Number :True Voice X * 0127 X Velocity Note On Note Off X X O O Effect Control After Touch Key s Ch s X X X X Pitch BendXX Control Change 0-95,102-119OOAssignable Prog Change:True# 0127 * 0127 099 Assignable System ExclusiveOO*1 System Common :Song Pos :Song Sel :Tune X X X O X X Automix System Real Time :Clock :Commands X X O O Automix, Effect Control Aux Messages :Local ON/OFF :All Notes OFF :Active Sense :Reset X X X X X X O O Notes MTC quarter frame message is recognized.(MTC IN & MIDI IN) *1: Bulk Dump/Request, Parameter Change/Request, and MMC. For MIDI Remote, ALL messages can be transmitted. Mode 1: OMNI ON, POLY Mode 3: OMNI OFF, POLY Mode 2: OMNI ON, MONO Mode 4: OMNI OFF, MONO O: Yes X: No PARTS LIST CONTENTS OVERALL ASSEMBLY. 2 BOTTOM ASSEMBLY. 5 REAR ASSEMBLY U. 12 CONTROL PANEL ASSEMBLY. 15 LCD ASSEMBLY.