欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 国外收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 功放/音响/收扩>
  • 老电视>
  • ImageVerifierCode 换一换

    Philips-HDD-086-Service-Manual电路原理图.pdf

    • 资源ID:84056       资源大小:4.03MB        全文页数:31页
    • 资源格式: PDF        下载积分:22积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Philips-HDD-086-Service-Manual电路原理图.pdf

    Micro Audio Jukebox HDD084/HDD085/HDD082/HDD086 All Versions 3141 785 30487 Version 1.7 TABLE OF CONTENTS ChapterTechnical Specification and Service hints.1 Safety Instructions2 Instructions for Use. 3 Mechanical Instructions. 4 Exploded view and Service parts list. 5 Factory Service Mode testing 6 Overall Block diagram. 7 Overall Electrical diagram. 8 Component layout 9 Revision list10Service Manual ©Copyright 2005 Philips Consumer Electronics B.V. Eindhoven, The Netherlands All rights reserved. No part of this publication may by reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronics, mechanical, photocopying, or otherwise without the prior permission of Philips 1.0 TECHNICAL SPECIFICATION and SERVICE HINTS General Dimensions (WxLx H) : 53 x 86 x 16.7 mm (2.1 x 3.4 x 0.7 inches) Weight : 78 g (2.8 oz) Output power : 2 x 5 mW (16 ohm) Frequency response : 20-20 000 Hz Equalizer : 5 band DSP controlled Hard disk : 1,0” micro HDD Capacity : 3GB Display : Black/White : 96 x 64 pixels Backlight : White Led Battery : 640 mAh Li-ion internal rechargeable battery Battery life time: >9hr File transfer rate using USB : 800kbyte/s Battery charging current 320 -420mA Maximum charging time : 4hrs Battery cutoff voltage: 3.4V Connections: Stereo headphone Mini USB (B-type) DC charger input Battery level detection Detection Level Typ. 4-step to 3-step voltage 3.95V 3-step to 2-step voltage 3,8V 2-step to 1-step voltage 3,7V Force Power Off voltage 3,4V Current consumption DC-IN SUPPLY (3.8V) Battery Charging Current 370mA typ. BATT. SUPPLY (3.4V) Power Off 75 dB THD (1kHz) : 0,5% - 1.0% Left-Right Channel Separation : 40dB typ. Left-Right Channel Balance : 0,5dB Supported playback format MP3 : 8 - 320 Kbps and VBR WMA : 32 - 192 Kbps Sample rates : 8, 11.025, 16, 22.050 32, 44.1, 48 ID3-tag support : Yes PC Connectivity : USB File Transfer For HDD084 via Windows Media Player 9 or 10 for music playback or Windows Explorer for general data (music playback disabled) For HDD082/HDD085/HDD086 via Windows Media Player 10 for music playback or Windows Explorer for general data (music playback disabled) Firmware and software upgrades For HDD084 1. Download the latest version of the Device Manager application from http:/www.philips.com/support. You may need to enter your language preference and the model number e.g.hdd084, to access the Device Manager application upgrade file. 2. Double click the downloaded execution file to start the installation of the Device Manager. 3. Once the installation is completed, connect the GoGear to the power supply with the AC/DC adapter. 4. Launch the Device Manager at Start->Programs->Philips GoGear HDD->Philips GoGear HDD on your PC 5. A dialogue box will pop up; click Upgrade to start the upgrading of the firmware. (Please do not disconnect the jukebox during the upgrading process as this interruption may damage the firmware!) 6. Follow all screen instructions to complete the firmware upgrade. 7. The Device Manager will close automatically once the success message is displayed. Close all opened application and then safely remove your GoGear micro jukebox by clicking on the icon in your task tray bar. When prompted, “The USB Mass Storage Device can now be safely removed from the system”, click OK and unplug your micro jukebox. 1.0 TECHNICAL SPECIFICATION and SERVICE HINTS 8. Once the GoGear micro jukebox is disconnected from the computer, the display will show “Firmware Upgrading” for a couple of seconds and then start up as usual. If the message does not disappear after 2 minutes, do a soft reset by pressing and holding the key and the volume + key for a couple of seconds. For HDD085/HDD082 1. Download the latest version of the Device Manager application from http:/www.philips.com/support. You may need to enter your language preference and the model number e.g. hdd085, to access the Device Manager application upgrade file. 2. Double click the downloaded execution file to start the installation of the Device Manager. 3. Connect the GoGear to the power supply with the AC/DC adapter and to the computer with the provided USB cable. Make sure that Windows Media Player along with any other applications are closed. 4. Launch the Philips Device Manager by double clicking the Device Manager icon at the task bar on your computer. 5. The Philips Device Manager will detect the connection of your GoGear and the application will automatically check on the server to see if an update is available and prompt user to download the updated firmware. Click YES to start the downloading. 6. A status bar will show the downloading progress of the firmware. Once the downloading is complete the application will prompt you to install the update onto your GoGear. Click YES to confirm7. The application will show the status of updating and at the end you need to click OK to complete the update. (Please do not disconnect the jukebox during the upgrading process as this interruption may damage the firmware!)8. Once the success message is displayed. Close Device Manager and all opened application and unplug your GoGear. Service Hints Rebuild database click Restore and OK to confirm and start restoring the unit to its factory setting. 3. Follow all screen instructions to complete the restoration. 4. The Device Manager will close automatically once the success message is displayed. Close all opened application and then safely remove your GoGear micro jukebox by clicking on the icon in your task tray bar. When prompted, “The USB Mass Storage Device can now be safely removed from the system”, click OK and unplug your micro jukebox. 5. Once the GoGear micro jukebox is disconnected from the computer, the display will show “Firmware Upgrading” for a couple of seconds and then start up as usual. For HDD086/HDD085/HDD082 1. Download the latest version of the Device Manager application from http:/www.philips.com/support. You may need to enter your language preference and the model number e.g.hdd085, to access the Device Manager application upgrade file. 2. Double click the downloaded execution file to start the installation of the Device Manager. 3. Connect the GoGear to the power supply with the AC/DC adapter and to the computer with the provided USB cable. Make sure that Windows Media Player along with any other applications are closed. 4. Launch the Philips Device Manager by double clicking the Device Manager icon at the task bar on your computer. 5. Select the REPAIR tab on the dialogue box and then click Repair to start repairing. IMPORTANT: All music click OK and unplug the GoGear from the computer. 1.0 TECHNICAL SPECIFICATION and SERVICE HINTS Capture the log file from device 1. Switch on the device in FSM mode by pressing and holding the Rec key and then the power key together. 2. Device will switch on and FSM main menu will be displayed 3. Scroll Down using the key to item 14 HDDinit 4. Press the key, HDD will be initialized, wait till HDD is initialized, you will get HDD INIT OK message once initialization is complete 5. Press to display main menu 6. Scroll down using the key to Item 19 Log to File, press thekey. 7. Wait till writing is completed you will get a message, writing done 8. Connect USB to device, you will see a file LOGINFO.TXT in the root, this is device log file, size will be around 3KB, copy the file 9. You will also see the pcloginfo.bin in the audio folder this is the PC log file. 10. Copy both of the above files to PC for future analysis by the Business if needed. If the HDD failed the HDDInit test then the device log may only be read off the LCD display with the Log to LCD option by following the steps below: 1. In the FSM main menu scroll down and select Log to LCD. 2. Press the key and then when prompted to “Press RIGHT KEY” message on display, press the key again you will see 5 parameters at a time on the display and then press again to see the next 5 parameters. 1.0 TECHNICAL SPECIFICATION and SERVICE HINTS Recovery procedure for flash corrupt problem If the device cannot be powered on but it can be detected by DFU program (device firmware upgrade application), it can be recovered by following the procedure below. Note: Close all applications e.g. Philips Device Manager before launch the DFU program. Run this program by Window XP only. For HDD084 only (MSC mode device) 1. Connect the DFU USB cable to the device first and then connect to your PC. 2. Launch the DFU program by unzip the Symphony.rar file and then double click the DFUAPP.exe file from Symphony folder. 3. Observe the dialogue box to ensure “DEVICE IS IN DFU MODE”. 4. Select Download and then click Browse to get the FWImage.ebn file from your PC. 5. Click Start Download to download the firmware to the device. 6. The program will stop once the successful message is display. 7. Disconnect DFU USB cable from the device. 8. Connect the device to the PC by normal USB cable and launch the Philips Device Manager to repair the device. (Download the latest version of the Device Manager application from Philips support website http:/www.philips.com/support)1.0 TECHNICAL SPECIFICATION and SERVICE HINTS For HDD086/HDD085/HDD082 (MTP mode device) 1. Unzip the Factory.rar file to your PC. You should find three folder name “Bootloader”, “DM” für Reparaturen sind Original-Ersatzteile zu verwenden.ILe norme di sicurezza esigono che lapparecchio venga rimessonelle condizioni originali e che siano utilizzati i pezzi di ricambioidentici a quelli specificati.“After servicing and before returning set to customer perform aleakage current measurement test from all exposed metal parts toearth ground to assure no shock hazard exist. The leakage currentmust not exceed 0.5mA.“CLASS 1LASER PRODUCT3122 110 03420GB Warning !Invisible laser radiation when open.Avoid direct exposure to beam.S Varning !Osynlig laserstrålning när apparaten är öppnad och spärrenär urkopplad. Betrakta ej strålen.SF Varoitus !Avatussa laitteessa ja suojalukituksen ohitettaessa olet alttiinanäkymättömälle laserisäteilylle. Älä katso säteeseen!DK Advarse !Usynlig laserstråling ved åbning når sikkerhedsafbrydere erude af funktion. Undgå udsaettelse for stråling.3Overview of controls and connections1 USB cable connector2 p Headphones jack3 5V DC Charging socket4 HOLD slider To disable key press5 LCD display Dynamically displays menu, options and track information6 VIEW To switch between root menu, library and now playing screens7 3 / 4 Scroll; SuperScroll; 3 / 4 J( / § Rewind / Fast forward; Up / Down to 1 level / Skip to previous / nexty 2; Power on / off and Play / Pause; confirms a menu setting8 Neckstrap eyelet9 Volume + / - Volume control0 REC Start or Stop Voice recording! PLAYLIST Add the current track to My Playlist MIC Microphonehdd084_ENG.qxd 6/16/05 4:37 PM Page 3

    注意事项

    本文(Philips-HDD-086-Service-Manual电路原理图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2025 收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开