Kenwood-KDC-515-S-Service-Manual电路原理图.pdf
Extension cord Parts No.CD mechanism(22P) W05-0618-00The MECHANISM OPERATION DESCRIPTION is the same as model KDC-S3007 and KDC-5050RG.Please refer to the service manual for model KDC-S3007(B51-7029-00) or KDC-5050RG(B51-7099-00).EJECTKDC-515SPWROFFLOUDSCAN RDM REP D.SCN M.RDMDISCDISCDABAUDMENUAUTOAMEDISPNAME.S45W 4XEJECT45W 4XKDC-5016PWROFFLOUDMENUDISPNAME.SSCAN RDM REP D.SCN M.RDMDISCDISCDABAUDAUTOAMEF1KDC-515SKDC-5016Escutcheon assy(B07-2195-08)Front glass assy(B10-3216-08)Panel assy(A64-2090-08)Escutcheon assy(B07-2195-08)Front glass assy(B10-3217-08)Panel assy(A64-2090-08)Plastic cabinet assy(A02-1494-08)Mounting hardware assy(J21-9585-08)Remote controller assy(A70-0883-05):KDC-5016Battery(size:AAA)Not supplied asservice partsDC cord(E30-4870-08)Screw set(N99-1688-08)Screw set(N99-1689-08)(J54-0611-08)StayEscutcheon(J CAR)(B07-2186-08)Lever(D10-4514-08)x2© 2000-2 PRINTED IN JAPANB51-7594-00 (N)1792CD RECEIVERSERVICE MANUALKDC-5016,515SKDC-5016,515S2CONTENTSBLOCK DIAGRAM .3COMPONENTS DESCRIPTION .4MICROCOMPUTERS TERMINAL DESCRIPTION .6TEST MODE .8ATTENTION .9PC BORD .10SCHEMATIC DIAGRAM .17EXPLODED VIEW.25PARTS LIST .27SPECIFICATIONS .34KDC-5016,515S3BLOCK DIAGRAMTUNERANTE PROME-VOLNOISE AMPPOWER ICCDu-COMCD-CHRSTLCD-DrREMO KEY MATRIXLCDBU5VSW 5V PNL 5V AUDIO 8VSW 14V SERVO7.5VILL 11VBU14VTU100, Q100-103IC1RST SWQ3IC2IC900IC901IC300IC500Q610, 611Q1 Q5 Q622, 625Q621, 624 Q618, 620 Q612, 614, 615REARFRONTREARFRONTBU5VSW5V PNL5V AIDIO 8V SERVO7.5VILL 11VFM AM CD CD-CHFRONT10K 10KREAR2FRONTREARCDAMFM CD-CH1250mV 1200mVFM CDAM CD-CHFM CDAM CD-CHFRONTREAR CD-CHCDAMFM:560mV:1660mV:2900mV:2930mV:400Hz 75KHz Dev:1KHz 0dB:400Hz 30% Mod:1KHz 0dB:2690mV:2650mV:2650mV:510mV:1530mV:2690mV:1530mV:510mV350mVAM+B FM+B SMETER SD SCL SDAIF COUNTREQ C REQ HDATACDATAHCLKCH-CONMUTERSTDATA SDATA LCEINHCLKSRQMUTECLKSW3SW2SW1DATASDATAMMO SWSTOPRSTLO/EJCS150mVSDASCLAMFM CD-CHCD:560mV:1660mV:2900mV:2930mVKDC-5016,515S4COMPONENTS DESCRIPTIONcircle6MAIN UNITRef.No. Component Name Application/Function Operation/Condition/CompatibilityIC1 784217AGF505 System MI-COM.IC2 S-80830ANNP Reset IC “Lo”: Detection voltage below 3.0VIC3 HD74HC27FP Mute logic 3 input NOR gate x3IC300 TDA7400D E-VOL. & N.C. MPXIC500 TDA7386 Power ICQ1 2SA1576A SW 5V ON when the base goes “Lo”.Q2 DTA124EUA Mute driver for Audio mute SW ON when the base goes “Lo”.Q3 DTA144EUA Changer reset SW ON when the base goes “Lo”.Q5 2SA1576A Panel 5V SW ON when the base goes “Lo” during the panel not detached.Q100 2SA1703-ANFM+B SWQ100 is turned ON when Q101s base goes “Hi”.Q101 DTC144EUA ON during FM reception.Q102 2SA1703-ANAM+B SWQ102 is turned ON when Q103s base goes “Hi”.Q103 DTC144EUA ON during AM reception.Q303 DTC144EUA E-VOL. mute SW E-VOL. is muted when the base goes “Hi”.Q350A,B DTC343TK Audio mute SW Audio pre-outs are muted when the base goes “Hi”Q351A,B DTC343TK Audio mute SW Audio pre-outs are muted when the base goes “Hi”Q500 DTC114YUA SVR SW POWER IC RESET is activated when the base goes “Hi”.Q600 2SC4081 BU detection(Momentary power down detection) ON when the base goes “Hi” during BU applied.Q601 2SC4081 ACC detection ON when the base goes “Hi” during ACC applied.Q602 2SA1703-ANP ANT SWQ602 is turned ON when Q603s base goes “Hi”.Q603 DTC114YUA ON during AM/FM reception.Q604 2SA1703-ANP CON SWQ604 is turned ON when Q607s base goes “Hi”.Q607 DTC114EUA ON during POWER ON mode except ALL OFF mode.Q605 2SA1576AP CON protectionProtect Q604 by turning ON when P-CON output is grounded.Q606 DTA124EUA Prevents Q605 tuning ON during start-up after power ON.Q610 2SB1565(E,F)BU 5V AVRInverted darlington connection.Q611 2SC4081 ON during BU applied.Q612 2SD1760 Illumination AVR ON when the base goes “Hi”.Q614 DTA124EUAIllumination AVR SW Q614 is turned ON when Q615s base goes “Hi”.Q615 DTC124EUAQ618 2SB1565(E,F)Servo AVRInverted darlington connection.Q620 2SC4081 Q618 is turned ON when Q620s base goes “Hi”.Q621 DTA124EUASW 14VAudio 8V AVR and Servo AVR ON/OFF control.Q624 DTC144EUA Q621 is turned ON when Q624s base goes “Hi”.Q622 2SB1565(E,F)Audio 8V AVRInverted darlington connection.Q625 2SC4081 Q622 is turned ON when Q625s base goes “Hi”.circle6CONTROL UNITRef.No. Component Name Application/Function Operation/Condition/CompatibilityIC900 LC75883E LCD driver with key-matrixIC901 RS-171 Remote control ICQ900 DTA124EUA Remote SW ON when the base goes “Lo”.Q903 DTA124EUA Key-matrix permission SW ON when the base goes “Lo”.KDC-5016,515S5COMPONENTS DESCRIPTIONcircle6CD PLAYER UNIT(X32-4700-00)Ref.No. Component Name Application/Function Operation/Condition/CompatibilityIC1 AN8806SB RF amplifierGeneration of RF signal based on the signals from the APCcircuit and pickup, and generation of servo error(focusing errorand tracking error)signals. Detection of dropout, anti-shock,track crossing and off-track conditions.IC2 MN662774KC3 CD signal processor bult-in MI-COM.Focusing, tracking, sled and spindle servo processing. Auto-matic adjustment(focusing, tracking, gain, offset andbalance)operations. Digital signal processing(DSP, PLL, sub-codes, CIRC error correction, audio data interpolaration)operations.IC4 BA5917AFP BTL driver Focusing coil, tracking coil, spindle motor and sled motor driverIC5 TA78L05F 5V AVRIC6 NJM4565MD Low pass filterQ1 2SB1188 APC LD power controlQ2 DTC124EUA P ON SW ON during the CD source selected.Q3 2SA1362(Y) A.8V SW A8V line ON/OFF controlQ4 2SA1362(Y) D.5V SW D5V line ON/OFF controlQ5 DTC124EUA MOTOR ON SW ON during CD loading or eject action .Q8 DTC124EUA GAIN CONTROL SWKDC-5016,515S6MICROCOMPUTERS TERMINAL DESCRIPTIONcircle6Terminal descriptionPinNo. Pin name I/O Description Processing Operation1 ST TYPE1 I IC2 setting terminal Lo: Initial value2 ST TYPE2 I IC2 setting terminal Lo: Initial value3 JS TYPE1 I Genuine/After market distinction terminal Hi: Genuine, “Lo”: After market4 TYPE1 I Destination type input terminal 15 TYPE2 I Destination type input terminal 26 TYPE3 I Destination type input terminal 37 NC O Not used8 NC O Not used9 VDD - Power supply connection terminal Connected to BU 5V lines.10 NC O Not used11 NC O Not used12 NC O Not used13 RDS DATA I Data input from the RDS decoder IC14 RDS QUAL I Quality input from the RDS decoder IC15 AFC O AFC control output Hi: During FM reception, “Lo”: During FM seek.16 FM/AM SD I SD input from the tuner pack Hi: Station detected, “Lo”: Not detected17 IF COUNT I Not used18 NC O Not used19 REMO I Data input from the remote control light sensor20 AM+B O AM+B control Hi: During AM reception.21 FM+B O FM+B control Hi: During FM reception.22 TEST - IC test terminal(Not used) Connected to GND23 IC2 SDA I/O Data input/output with the E-VOL. IC24 IC2 SCK O Clock output to the E-VOL. IC25 MUTE O Mute control output Hi: Mute ON, “Lo”: Mute OFF26 SW5V O SW 5V control output Lo: POWER ON mode or during CD loading or eject action.27 F/E DATA I/O Data input/output with the front end28 F/E CLK O Clock output to the front end29 CH CON O Changer control Hi: ON, “Lo”: Standby30 CH REQH O Request output to changers Lo: Request31 CD MUTE I Muting request from the MI-COM. of CD mecha. Lo: Mute request32 CD MRST O Reset output to the MI-COM. of CD mecha. Lo: Reset33 CD MSTOP O Stop request to the MI-COM. of CD mecha. Lo: Stop34 CD LO/EJ I/O CD mecha. loading/Eject switching output Lo: Loading, “Hi”: Eject, “Hi-Z”: Stop35 CD LMON O CD mechanism loading motor control output Hi: CD loading or eject action, “Lo”: other36 CD SW3 I Down & limit switch detection input Hi: Chucking, “Lo”: Pickup most inner position37 VDD - Power supply connection terminal Connected to BU 5V lines.38 X2 - Main clock resonator connection terminal39 X1 - Main clock resonator connection terminal40 VSS - Ground connection terminal Connected to GND.41 XT2 - Sub clock resonator connection terminal42 XT1 - Sub clock resonator connection terminal43 RESET I Reset input terminal Lo: System reset44 NC O Not used45 RDS CLK I Clock input from the RDS decoder IC46 CH REQC I Request input from changers Lo: Request47 LCD DATAL I Data input from the LCD driver IC48 CD SW2 I 12cm disc detection terminal When 12cm disc was detected, the input becomes “Lo” temporarily.49 CD SW1 I Loading detection Lo: CD chucking.50 NC O Not used51 AVDD - A/D converter power supply connection terminal Connected to BU 5V lines.KDC-5016,515S7MICROCOMPUTERS TERMINAL DESCRIPTIONPinNo. Pin name I/O Description Processing Operation52 AVREF0 - A/D converter reference voltage input terminal Connected to BU 5V lines.53 PHONE I PHONE detection input 1V or less: TEL MUTE, 2.5V or greater: NAVI MUTE54 NC I Not used Pull down to GND.55 NOISE I Noise detection input56 S-METER I S-meter input from the front end57 NC I Not used Pull down to GND.58 NC I Not used Pull down to GND.59 NC I Not used Pull down to GND.60 NC I Not used Pull down to GND.61 AVSS - A/D, D/A converter ground connection terminal Connected to GND.62 NC O Not used63 NC O Not used64 AVREF1 - D/A converter reference voltage input terminal65 CH DATAC I Data input from changers66 CH-DATAH O Data output to changers67 CH CLK I/O Clock input/output with changers68 LCD DATAL I Data input from the LCD driver IC69 LCD DATAS O Data output to the LCD driver IC70 LCD CLK O Clock output to the LCD driver IC71 NC O Not used72 BEEP O BEEP sound output73 NC O Not used74 PNL DET1 I Panel detaching detection input Hi: Panel detached.75 NC O Not used76 LCD INH O INH output to the LCD driver IC Lo: LCD indication OFF.77 LCD CE O CE output to the LCD driver IC Hi: Active78 SRT SW1 I SRT position detection inputPanel: (SW1, SW2)=(Hi, Hi)Slide : (SW1, SW2)=(Hi, Lo)79 SRT SW2 I SRT position detection input Mask : (SW1, SW2)=(Lo, Lo)80 NC O Not used81 NC O Not used82 NC O Not used83 NC O Not used84 NC O Not used85 NC O Not used86 NC O Not used87 AMP SVR O Power lC reset outputWhen the momentary power down, after ACC OFF is detectedand after POWER OFF, the output goes “Hi” temporarily.88 AMP STBY O Power IC standby control output Hi: POWER ON mode89 AMP MUTE O Power IC mute control output Lo: Mute90 NC O Not used91 ILL ON O Illumination AVR ON/OFF control output Hi: AVR ON92 P ON O Microprocessor peripheral power supply control output Hi: ACC ON or during CD loading or eject action.93 SMALL I Small lights detection input Lo: During vehicle small lamps turn on.94 P ANT O Antenna control output Hi: During FM/AM reception.95 P CONT O Power control output Hi: POWER ON mode except ALL OFF mode.96 ACC DET I ACC detection input Hi: ACC OFF, “Lo”: ACC 0N97 BU DET I Momentary power down detection input Hi: When momentary power down detected or BU OFF, “Lo”: BU ON98 AMP CONT O External amp. control output99 NC O Not used100 VSS - Ground connection terminal Connected to GND.KDC-5016,515S8TEST MODETEST MODE SPECIFICATIONS(1) How to enter the test modeWhile holding the FM and Preset 6 keys simultaneously,reset the unit.All indicators and display segments are ON at the startof test mode.(2) How to exit from the test modeReset the unit.(Note) The test mode cannot be canceled by turningAcc OFF, power OFF or momentary power down.(3) Test mode specifications of the CD receiverEach press of the Track Up key jumps to the followingtracks.No. 9 No. 15 No. 10 No. 11 No. 12 No.13 No. 14 No. 9 (return to beginning)Pressing the Track Down key jumps to the previous trackto the track being played.(4) Audio The volume is -10 dB (displayed as 30). LOUD is OFF, and CRSC is also OFF whether the func-tion is provided or not. With the Bass/Treble and Balance/Fader controls,pressing the Up/Down key switch the setting alter-nately to:Full Boost Full Cut Full Boost, Full Right Full Left Full Right, or Full Front Full Rear Full Front. With the high-pass filter, pressing the Up key sets itto Through/100 Hz/200 Hz and pressing the Down keysets it to 200 Hz/100 Hz/Through. Other adjustments function in the same way as nor-mal mode.(5) Backup current measurementWhen the unit is reset (backup turned on) while Acc isOFF or when Acc is turned OFF in test mode, the MUTEterminal goes on in 2 seconds, instead of 1.5 second.(The panel, CD, C and MD mechanisms are not acti-vated at this time.)(6) Security code registration after E2PROM replacementservicing (E/M type only)1. Enter the test mode. (See (1) How to enter the testmode.)2. Press the SRC key to set All OFF.3. Press and hold the AUDIO key for 1 second to entermenu mode.4. Press the FM/AM key to select “SECURITY”.5. Press and hold the Track Up/Down for 2 seconds.6. Enter the code by pressing the Preset 1, 2, 3 and 4keys.Example: To enter “3510“, Press the Preset 1 key 4 times. Press the Preset 2 key 6 times. Press the Preset 3 key 2 times. Press the Preset 4 key once.7. Press and hold the DISPLAY key for 3 seconds todisplay “APPROVED“.8. Quit the test mode (See (2) How to exit from the testmode.)(7) How to clear the simple security code (K type only)1. While the code is requested, press and hold the DISPkey and press and hold the VOL Up key for 3 sec-onds.(“.“disappears.)2. Enter “KCAR” from the remote control unit. (Sameoperation as the '98 model) Press numeric key 5 twice then press the Track Upkey. (This enters “K“.) Press numeric key 2 three times then press the TrackUp key. (This enters “A“.) Press numeric key 2 once then press the Track Upkey. (This enters “A“.) Press numeric key 7 twice then press the Track Upkey. (This enters “A“.)3. The security is canceled and the unit enters theTUNER mode.(8) Other The DNPP/SBF key of the remote control unit (RC-510) functions as the menu mode ON/OFF key. The OPEN/CLOSE key of the remote control unit (RC-510) functions as the audio adjustment mode ON/OFF key. The menu is displayed by displaying only the requiredfeatures. Message such as “CODE OFF“ is not displayed whenpower is turned ON. The contrast can be adjusted only to 0/5/10 using theUp/Down keys.KDC-5016,515S9ATTENTIONAssembly of FPC(Flexible PC board) onto Roller assyTurn Roller assy by 4 times.Hook the end of Roller assy to the tongue.Insert the FPC into the slit of Roller assy then release the end of Roller assy and the tongue.tongueTurn 4 times.End of Roller