欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 国外收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 功放/音响/收扩>
  • 老电视>
  • ImageVerifierCode 换一换

    Jvc-UXLP-5-Service-Manual电路原理图.pdf

    • 资源ID:76197       资源大小:5.19MB        全文页数:34页
    • 资源格式: PDF        下载积分:22积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Jvc-UXLP-5-Service-Manual电路原理图.pdf

    SERVICE MANUALCOPYRIGHT © 2009 Victor Company of Japan, LimitedNo.MB6982009/10MICRO COMPONENT SYSTEMMB698200910SERVICE MANUALUX-LP5B, UX-LP5E, UX-LP5EN, UX-LP5EV, UX-LP5J, UX-LP5C, UX-LP5A, UX-LP5US, UX-LP5UB, UX-LP5UP, UX-LP5UTCOPYRIGHT © 2009 Victor Company of Japan, LimitedLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-52 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-93 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-104 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-145 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14CA-UXLP5SP-UXLP5SP-UXLP5(for Europe)1-2 (No.MB698)SPECIFICATIONUX-LP5 for EuropeSpecifications and appearance are subject to change without prior notice.Amplifier sectionOUTPUT POWER 60 W (30 W + 30 W) at 6 (10% THD)Speakers/Impedance 6 - 16 Audio input AUDIO IN 500 mV/47 k (at “LEVEL 1”)250 mV/47 k (at “LEVEL 2”)125 mV/47 k (at “LEVEL 3”)Digital input USB MEMORYTuner sectionFM tuning range 87.50 MHz - 108.00 MHzAM (MW) tuning range 522 kHz - 1 629 kHzCD player sectionDynamic range 88 dBSignal-to-noise ratio 85 dBWow and flutter ImmeasurableiPod sectioniPod output power DC 5 V 500 mAVIDEO OUT CompositeUSB storageUSB specification Compatible with USB 2.0 Full SpeedCompatible device Mass storage classCompatible file system FAT16, FAT32Bus power supply DC 5 V 500 mAGeneralPower requirements AC 230 V , 50 HzPower consumption 35 W (power on)8 W (standby mode)1 W or less (Ecology Mode)Dimensions (approx) 165 mm × 259 mm × 258 mm (W × H × D)Mass (approx) 1.9 kgSpeakersSpeaker units 10 cm × 1; 1.5 cm × 1Impedance 6 Dimensions (approx.) 140 mm × 250 mm × 188 mm (W × H × D)Mass (approx.) 1.4 kg each(No.MB698)1-3UX-LP5J/CSpecifications and appearance are subject to change without prior notice.Amplifier sectionOUTPUT POWER 35 W per channel, min. RMS, driven into 4 at 1 kHz with no more than 10%total harmonic distortionSpeakers/Impedance 6 - 16 Audio input AUDIO IN 500 mV/47 k (at “LEVEL 1”)250 mV/47 k (at “LEVEL 2”)125 mV/47 k (at “LEVEL 3”)Tuner sectionFM tuning range 87.5 MHz - 108.0 MHzAM tuning range 530 kHz - 1 710 kHzCD player sectionDynamic range 88 dBSignal-to-noise ratio 85 dBWow and flutter ImmeasurableiPod sectioniPod output power DC 5 V 500 mAVIDEO OUT CompositeGeneralPower requirements AC 120 V , 60 HzPower consumption 35 W (power on)8 W (standby mode)1 W or less (Ecology Mode)Dimensions (approx.) 165 mm × 259 mm × 258 mm (6-1/2 inches × 10-1/4 inches × 10-3/16 inches) (W × H × D)Mass (approx.) 1.9 kg (4.2 lbs)SpeakersSpeaker units 10 cm (3-15/16 inches) × 1; 1.5 cm (5/8 inch) × 1Impedance 6 Dimensions (approx.) 140 mm × 250 mm × 188 mm (5-9/16 inches × 9-7/8 inches × 7-7/16 inches) (W × H × D)Mass (approx.) 1.4 kg (3.1 lbs) each1-4 (No.MB698)UX-LP5 for Asia, AustraliaSpecifications and appearance are subject to change without prior notice.Amplifier sectionOUTPUT POWER 60 W (30 W + 30 W) at 6 (10% THD)Speakers/Impedance 6 - 16 Audio input AUDIO IN 500 mV/47 k (at “LEVEL 1”)250 mV/47 k (at “LEVEL 2”)125 mV/47 k (at “LEVEL 3”)Digital input USB MEMORYTuner sectionFM tuning range 87.50 MHz - 108.00 MHzAM tuning range 531 kHz - 1 710 kHz (in 9 kHz spacing)530 kHz - 1 710 kHz (in 10 kHz spacing)CD player sectionDynamic range 88 dBSignal-to-noise ratio 85 dBWow and flutter ImmeasurableiPod sectioniPod output power DC 5 V 500 mAVIDEO OUT CompositeUSB storageUSB specification Compatible with USB 2.0 Full SpeedCompatible device Mass storage classCompatible file system FAT16, FAT32Bus power supply DC 5 V 500 mAGeneralPower requirements AC 110 V - 127 V/AC 220 V - 240 V (adjustable with the voltage selector), 50 Hz/60 HzAC 240 V , 50 Hz (only Australia)AC 220 V , 50 Hz (only Hong Kong)Power consumption 35 W (power on)8 W (standby mode)1 W or less (Ecology Mode)Dimensions (approx) 165 mm × 259 mm × 258 mm (W × H × D)Mass (approx) 1.9 kgSpeakersSpeaker units 10 cm × 1; 1.5 cm × 1Impedance 6 Dimensions (approx.) 140 mm × 250 mm × 188 mm (W × H × D)Mass (approx.) 1.4 kg each(No.MB698)1-5SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15µF AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE1-6 (No.MB698)1.5 Preventing static electricityElectrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laserdiode in the traverse unit (optical pickup). Take care to prevent this when performing repairs.1.5.1 Grounding to prevent damage by static electricityStatic electricity in the work area can destroy the optical pickup (laser diode) in devices such as laser products. Be careful to use proper grounding in the area where repairs are being performed. (1) Ground the workbenchGround the workbench by laying conductive material (such as a conductive sheet) or an iron plate over it before placing thetraverse unit (optical pickup) on it.(2) Ground yourselfUse an anti-static wrist strap to release any static electricity built up in your body. (3) Handling the optical pickup In order to maintain quality during transport and before installation, both sides of the laser diode on the replacement opticalpickup are shorted. After replacement, return the shorted parts to their original condition. (Refer to the text.) Do not use a tester to check the condition of the laser diode in the optical pickup. The tester's internal power source can easilydestroy the laser diode. 1.6 Handling the traverse unit (optical pickup)(1) Do not subject the traverse unit (optical pickup) to strong shocks, as it is a sensitive, complex unit. (2) Cut off the shorted part of the flexible cable using nippers, etc. after replacing the optical pickup. For specific details, refer to thereplacement procedure in the text. Remove the anti-static pin when replacing the traverse unit. Be careful not to take too long atime when attaching it to the connector. (3) Handle the flexible cable carefully as it may break when subjected to strong force. (4) I t is not possible to adjust the semi-fixed resistor that adjusts the laser power. Do not turn it.1.7 Attention when traverse unit is decomposed*Please refer to “Disassembly method“ in the text for the pickup unit. Apply solder to the short land sections before the card wire is disconnected from the connecto on the servo board. (If the card wireis disconnected without applying solder, the pickup may be destroyed by static electricity.) In the assembly, be sure to remove solder from the short land sections after connecting the card wire.1MConductive material(conductive sheet) or iron palate(caption)Anti-static wrist strapSolder short part(No.MB698)1-71.8 Important for laser products1.CLASS 1 LASER PRODUCT 2.CAUTION : (For U.S.A.) Visible and/or invisible class II laser radiationwhen open. Do not stare into beam.(Others) Visible and/or invisible class 1M laser radiationwhen open. Do not view directly with optical instruments. 3.CAUTION : Visible and/or invisible laser radiation whenopen and inter lock failed or defeated. Avoid directexposure to beam.4.CAUTION : This laser product uses visible and/or invisible laser radiation and is equipped with safety switches which prevent emission of radiation when the drawer is open and the safety interlocks have failed or are defeated. It is dangerous to defeat the safety switches.5.CAUTION : If safety switches malfunction, the laser is ableto function. 6.CAUTION : Use of controls, adjustments or performance of procedures other than those specified here in may result in hazardous radiation exposure. REPRODUCTION AND POSITION!Please use enough caution not to see the beam directly or touch it in case of an adjustment or operationcheck. CAUTION:INVISIBLE LASER RADIATION WHEN OPENDO NOT STARE INTO BEAMDANGER:INVISIBLE LASER RADIATION WHEN OPENAVOID DIRECT EXPOSER TO THE BEAM1-8 (No.MB698)1.9 Importance administering point on the safetyR27R29R16HS1R31R30L5D9L7R26R14CN3R25D18C26R28R13U6D17V7V5V3V4C18C1V2C2D3D4C19C17C31PVCC PVCCPGND PGNDGNDGNDC3 C4D2D1V1R9F1T2.5AH250VR32L1HS2T1D14JP9F2R15R22CN2CN5C25C27C16C15C13C12C20CN4C14C21CN1R10R23C11JP8D10GND3GND2L4L3L6D19D12GND5VGND5VD16D11D13FL+FL+-25VECO5VEGNDGNDGND5VD5VD12VR2R1C6D6C5C23C10C9C7C8C22C24C28L2U2U3R8R4R24R3R6R5R7R19R12R11D8JP5JP3 JP4JP1JP2JP6SW1D5JP7R18R20R21Graphic symbol mark (This symbol means slow blow type fuse.)FOR CONTINUED PROTECTION AGAINST RISKOF FIRE, REPLACE ONLY WITH SAME TYPEAND RATING OF FUSES ;should be read as follows ;F901 : T1.6AH 250V F901 : T1.6AH 250VFull Fuse Replacement MarkingFUSE CAUTIONLe symbole graphique (Ce symbole signifiefusible de type a fusion lent.)POUR UNE PROTECTION CONTINUE CONTREDES RISQUES D'INCENDIE, REMPLACERSEULEMENT PAR UN FUSIBLE DU MEME TYPE ;Marquage Pour Le RemplacementComplet De FusiblePRECAUTIONS SUR LES FUSIBLESdoit etre interprete comme suit ;slow blow type / type a fusion lent(No.MB698)1-9SECTION 2SPECIFIC SERVICE INSTRUCTIONSThis service manual does not describe SPECIFIC SERVICE INSTRUCTIONS.1-10 (No.MB698)SECTION 3DISASSEMBLY3.1 Main body (Used figure are UX-LP5E)3.1.1 Removing the Top cabinet (See Fig.1, 2)(1) Remove the six screws A attaching the both side of the Topcabinet. (See Fig.1)Fig.1(2) Remove the five screws B attaching the Top cabinet. (SeeFig.2)Fig.23.1.2 Removing the SMPS board (See Fig.3)(1) Remove the four screws C attaching the SMPS board.(2) Disconnect the connector wires from MCU board connect-ed to connectors CN2 and CN3 of the SMPS board.Fig.3AABBCCCN3CN2

    注意事项

    本文(Jvc-UXLP-5-Service-Manual电路原理图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2025 收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开