Ampeg_svt_csb0003 电路图 维修原理图.pdf
-
资源ID:176552
资源大小:55.13KB
全文页数:2页
- 资源格式: PDF
下载积分:8积分
会员登录下载
三方登录下载:
友情提示
2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。
|
Ampeg_svt_csb0003 电路图 维修原理图.pdf
SLM Electronics #CSB0003 A Division of St. Louis Music, Inc 11880 Borman DrService Department St. Louis, MO 63146Phone 800 738 7563 Phone 314 569 0141Fax 314 567 7278 November 6, 1997 Customer Service Bulletin Units Affected: SVT-2PROJ units serial numbered T2PJJ40001 through T2PJJ40042 SVT-2PROJ units serial numbered T2PJJ80001 through T2PJJ80010 SVT-CLJ units serial numbered TCLJJ40001 through TCLJJ40032 SVT-CLJ units serial numbered TCLJJ60001 through TCLJJ60002 SVT-CLJ units serial numbered TCLJJ90001 through TCLJJ90020 Note: A number of units in these serial number ranges have been factory modified to correct the problem. These units do not need to be modified in the field. They can be identified by the presence of a “Star Quality” label affixed to the outside of the shipping carton adjacent to the serial number/Bar code label. Concern: AC mains fuse for filament transformer would fail prematurely during normal operation when turning unit on as a result of a design change to use IEC approved fuse beginning with 1/1/97 production. Replacement with larger value fuse would solve false tripping problem but would not always provide adequate protection against damage during severe fault condition. Corrective Action: Add two each 3A in-rush current limiters (ICLs) that have been prepared with .187” Fast-on connectors (SLME part number 97-123-23) to the filament transformer primary circuit as follows: 1. Disconnect the AC power from the unit. 2. Remove lower chassis assembly from cabinet and view from bottom. 3. On the 07-319-xx AC termination PC board, remove blue and gray leads from tabs J17 and J18. 4. Add one 97-123-23 ICL assembly in series with the blue transformer lead and tab J17, and one in series with the gray lead and J18 by attaching the female Fast-on connector of ICL to the tab on the printed circuit board and the male Fast-on to transformer lead. 5. Secure the assembly with a cable tie to other AC wires so that no leads are touching other parts. 6. Replace the fuse (F2) with a T1.25A (SLME part number 23-512-05). 7. Remove any fuse label so that “100VAC T1.25A” is visible on the printed circuit board. 8. Reassemble and check out unit for proper operation. 收音机爱好者资料库 Ra d i o Fa n s .CN Note: For best operation of ICLs do not rapidly turn the amplifier off and on. These devices are self- heating and require a short time to cool and return to their protective, “high resistance” state. 07-319-xx AC Termination board as viewed from inside lower chassis Add one 97-123-23 ICL assembly in series with J17 and the blue transformer lead and one in series with J18 and the gray transformer lead. 收音机爱好者资料库 Ra d i o Fa n s .CN