    NAD-CI9060-pwr-sm 维修电路原理图.pdf

    • 资源ID:152483       资源大小:2.76MB        全文页数:14页
    • 资源格式: PDF        下载积分:18积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    NAD-CI9060-pwr-sm 维修电路原理图.pdf

    NADSERVICE MANUALCI 9060/9120CI 9060/9120SIX CHANNEL AMPLIFIERTWELVE CHANNEL AMPLIFERSIX CHANNEL AMPLIFIERTWELVE CHANNEL AMPLIFER RadioFans.CN 收音机爱 好者资料库PRODUCT SAFETY SERVICING GUIDELINES CAUTION : DO NOT ATTEMPT TO MODIFY THIS PRODUCT INANY WAY. NEVER PERFORM CUSTOMIZED INSTALLATIONSWITHOUT MANUFACTURERS APPROVAL. UNAUTHORIZEDMODIFICATIONS WILL NOT ONLY VOID THE WARRANTY, BUTMAY LEAD TO YOUR BEING LIABLE FOR ANY RESULTINGPROPERTY DAMAGE OR USER INJURY.SERVICE WORK SHOULD BE PERFORMED ONLY AFTER YOUARE THOROUGHLY FAMILIAR WITH ALL OF THE FOLLOWINGSAFETY CHECKS AND SERVICING GUIDELINES. TO DOOTHERWISE, INCREASES THE RISK OF POTENTIAL HAZARDSAND INJURY TO THE USER. WHILE SERVICING, USE AN ISOLATION TRANSFORMER FORPROTECTION FROM AC LINE SHOCK.SAFETY CHECKSAFTER THE ORIGINAL SERVICE PROBLEM HAS BEENCORRECTED. A CHECK SHOULD BE MADE OF THEFOLLOWING.SUBJECT : FIRE & SHOCK HAZARD1. BE SURE THAT ALL COMPONENTS ARE POSITIONED INSUCH A WAY AS TO AVOID POSSIBILITY OF ADJACENTCOMPONENT SHORTS. THIS IS ESPECIALLY IMPORTANTON THOSE MODULES WHICH ARE TRANSPORTED TO ANDFROM THE REPAIR SHOP. 2. NEVER RELEASE A REPAIR UNLESS ALL PROTECTIVEDEVICES SUCH AS INSULATORS, BARRIERS, COVERS,SHIELDS, STRAIN RELIEFS, POWER SUPPLY CORDS, ANDOTHER HARDWARE HAVE BEEN REINSTALLED PERORIGINAL DESIGN. BE SURE THAT THE SAFETY PURPOSEOF THE POLARIZED LINE PLUG HAS NOT BEEN DEFEATED.3. SOLDERING MUST BE INSPECTED TO DISCOVER POSSIBLECOLD SOLDER JOINTS, SOLDER SPLASHES OR SHARPSOLDER POINTS. BE CERTAIN TO REMOVE ALL LOOSEFOREIGN PARTICLES.4. CHECK FOR PHYSICAL EVIDENCE OF DAMAGE ORDETERIORATION TO PARTS AND COMPONENTS. FORFRAYED LEADS, DAMAGED INSULATION (INCLUDING ACCORD). AND REPLACE IF NECESSARY FOLLOW ORIGINALLAYOUT, LEAD LENGTH AND DRESS.5. NO LEAD OR COMPONENT SHOULD TOUCH A RECEIVINGTUBE OR A RESISTOR RATED AT 1 WATT OR MORE. LEADTENSION AROUND PROTRUDING METAL SURFACES MUSTBE AVOIDED.6. ALL CRITICAL COMPONENTS SUCH AS FUSES,FLAMEPROOF RESISTORS, CAPACITORS, ETC. MUST BEREPLACED WITH EXACT FACTORY TYPES, DO NOT USEREPLACEMENT COMPONENTS OTHER THAN THOSESPECIFIED OR MAKE UNRECOMMENDED CIRCUITMODIFICATIONS.7. AFTER RE-ASSEMBLY OF THE SET ALWAYS PERFORM ANAC LEAKAGE TEST ON ALL EXPOSED METALLIC PARTS OFTHE CABINET, (THE CHANNEL SELECTOR KNOB, ANTENNATERMINALS. HANDLE AND SCREWS) TO BE SURE THE SETIS SAFET TO OPERATE WITHOUT DANGER OF ELECTRICALSHOCK. DO NOT USE A LINE ISOLATION TRANSFORMERDURING THIS TEST USE AN AC VOLTMETER, HAVING 5000OHMS PER VOLT OR MORE SENSITIVITY, IN THEFOLLOWING MANNER; CONNECT A 1500 OHM 10 WATTRESISTOR, PARALLELED BY A .15 MFD, 150V AC TYPECAPACITOR BETWEEN A KNOWN GOOD EARTH GROUND(WATER PIPE, CONDUIT, ETC.) AND THE EXPOSEDMETALLIC PARTS, ONE AT A TIME. MEASURE THE AC VOLTAGE ACROSS THE COMBINATIONOF 1500 OHM RESISTOR AND .15 MFD CAPACITOR. REVERSE THE AC PLUG AND REPEAT AC VOLTAGEMEASUREMENTS FOR EACH EXPOSED METALLIC PART. VOLTAGE MEASURE MUST NOT EXCEED 75 VOLTS R.M.S.THIS CORRESPONDS TO 0.5 MILLIAMP AC ANY VALUEEXCEEDING THIS LIMIT CONSTITUTES A POTENTIALSHOCK HAZARD AND MUST BE CORRECTED IMMEDIATELY.SUBJECT : GRAPHIC SYMBOLSSUBJECT : TIPS ON PROPER INSTALLATION1. NEVER INSTALL ANY PRODUCT IN A CLOSED-IN RECESS,CUBBYHOLE OR CLOSELY FITTING SHELF SPACE. OVEROR CLOSE TO HEAT DUCT, OR IN THE PATH OF HEATEDAIR FLOW.2. AVOID CONDITIONS OF HIGH HUMIDITY SUCH AS:OUTDOOR PATIO INSTALLATIONS WHERE DEW IS AFACTOR, NEAR STEAM RADIATORS WHERE STEAMLEAKAGE IS A FACTOR, ETC.3. AVOID PLACEMENT WHERE DRAPERIES MAY OBSTRUCTREAR VENTING. THE CUSTOMER SHOULD ALSO AVOID THEUSE OF DECORATIVE SCARVES OR OTHER COVERINGSWHICH MIGHT OBSTRUCT VENTILATION.4. WALL AND SHELF MOUNTED INSTALLATIONS USING ACOMMERCAL MOUNTING KIT MUST FOLLOW THE FACTORYAPPROVED MOUNTING INSTRUCTIONS A PRODUCTMOUNTED TO A SHELF OR PLATFORM MUST RETAIN ITSORIGINAL FEET (OR THE EQUIVALENT THICKNESS INSPACERS) TO PROVIDE ADEQUATE AIR FLOW ACROSSTHE BOTTOM, BOLTS OR SCREWS USED FOR FASTENERSMUST NOT TOUCH ANY PARTS OR WIRING. PERFORMLEAKAGE TEST ON CUSTOMIZED INSTALLATIONS.5. CAUTION CUSTOMERS AGAINST THE MOUNTING OF APRODUCT ON SLOPING SHELF OR A TILTED POSITION,UNLESS THE PRODUCT IS PROPERLY SECURED.6. A PRODUCT ON A ROLL-ABOUT CART SHOULD BE STABLEON ITS MOUNTING TO THE CART. CAUTION THECUSTOMER ON THE HAZARDS OF TRYING TO ROLL A CARTWITH SMALL CASTERS ACROSS THRESHOLDS OR DEEPPILE CARPETS.7. CAUTION CUSTOMERS AGAINST THE USE OF A CART ORSTAND WHICH HAS NOT BEEN LISTED BY UNDERWRITERSLABORATORIES, INC. FOR USE WITH THEIR SPECIFICMODEL OF TELEVISION RECEIVER OR GENERICALLYAPPROVED FOR USE WITH T.V.S OF THE SAME ORLARGER SCREEN SIZE.8. CAUTION CUSTOMERS AGAINST THE USE OF EXTENSIONCORDS, EXPLAIN THAT A FOREST OF EXTENSIONSSPROUTING FROM A SINGLE OUTLET CAN LEAD TODISASTROUS CONSEQUENCES TO HOME AND FAMILY.THE LIGHTNING FLASH WITH ARROWHEAD SYMBOL, WITHIN ANEQUILATERAL TRIANGLE, IS INTENDED TO ALERT THE USER TO THEPRESENCE OF UNINSULATED “DANGEROUS VOLTAGE” WITHIN THEPRODUCTS ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE TOCONSTITUTE A RISK OF ELECTRIC SHOCK.THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIANGLE ISINTENDED TO ALERT THE USER TO THE PRESENCE OF IMPORTANTOPERATING AND MAINTENANCE (SERVICING) INSTRUCTIONS IN THELITERATURE ACCOMPANYING THE APPLIANCE.2RadioFans.CN 收音机爱 好者资料库SERVICING PRECAUTIONSCAUTION : Before servicing the A/V Receiver covered by thisservice data and its supplements and addends, read and follow theSAFETY PRECAUTIONS. NOTE : if unforeseen circumstancescreate conflict between the following servicing precautions and anyof the safety precautions in this publication, always follow the safetyprecautions.Remember Safety First:General Servicing Precautions1. Always unplug the A/V Receiver AC power cord from the ACpower source before:(1) Removing or reinstalling any component, circuit board,module, or any other assembly.(2) Disconnecting or reconnecting any internal electrical plug orother electrical connection.(3) Connecting a test substitute in parallel with an electrolyticcapacitor.Caution : A wrong part substitution or incorrect polarity installationof electrolytic capacitors may result in an explosion hazard.2. Do not spray chemicals on or near this A/V Receiver or any of itsassemblies.3. Unless specified otherwise in this service data, clean electricalcontacts by applying an appropriate contact cleaning solution tothe contacts with a pipe cleaner, cottontipped swab, orcomparable soft applicator.Unless specified otherwise in this service data, lubrication ofcontacts is not required.4. Do not defeat any plug/socket B+ voltage interlocks with whichinstruments covered by this service manual might be equipped.5. Do not apply AC power to this A/V Receiver and/or any of itselectrical assemblies unless all solid-state device heat sinks arecorrectly installed.6. Always connect test instrument ground lead to the appropriateground before connecting the test instrument positive lead. Alwaysremove the test instrument ground lead last.Insulation Checking ProcedureDisconnect the attachment plug from the AC outlet and turn thepower on. Connect an insulation resistance meter(500V) to theblades of the attachment plug. The insulation resistance betweeneach blade of the attachment plug and accessible conductive parts(Note 1) should be more than 1M-ohm.Note 1 : Accessible Conductive Parts including Metal panels, Inputterminals, Earphone jacks, etc.Electrostatically Sensitive (ES) DevicesSome semiconductor (solid state) devices can be damaged easily bystatic electricity. Such components commonly are calledElectrostatically Sensitive (ES) Devices. Examples of typical Esdevices are integrated circuits and some field effect transistors andsemiconductor chip components.The following techniques should be used to help reduce theincidence of component damage caused by static electricity.1. Immediately before handling any semiconductor component orsemiconductor-equipped assembly, drain off any electrostaticcharge on your body by touching a known earth ground.Alternatively, obtain and wear a commercially availabledischarging wrist strap device, which should be removed forpotential shock reasons prior to applying power to the unit undertest.2. After removing an electrical assembly equipped with ES devices,place the assembly on a conductive surface such as aluminumfoil, to prevent electrostatic charge buildup or exposure of theassembly.3. Use only a grounded-tip soldering iron to solder or unsolder ESdevices.4. Use only an antistatic solder removal device. Some solderremoval devices not classified a “anti-static” can generateelectrical charges sufficient to damage ES devices.5. Do not use freonpropelled chemicals. These can generateelectrical charge sufficient to damage ES devices.6. Do not remove a replacement ES device from its protectivepackage until immediately before you are ready to install it. (Mostreplacement ES devices are packaged with leads electricallyshorted together by conductive foam, aluminum foil, orcomparable conductive material).7. lmmediately before removing the protective material from theleads of a replacement ES device, touch the protective material tothe chassis or circuit assembly into which the device will beinstalled.Caution : Be sure no power is applied to the chassis or circuit, andobserve all other safety precautions.8. Minimize bodily motions when handing unpackaged replacementES devices. (Normally harmless motion such as the brushingtogether of your clothes fabric or the lifting of your foot from acarpeted floor can generate static electricity sufficient to damagean ES device.)3SpecificationsPower Rating85 Watts continuous average power into 6 Ohms at any frequency between 20Hz and 20kHz with all channels driven at less than 0.03% THD.86 Watts continuous average power into 4 Ohms at any frequency between 20Hz and 20kHz with all channels driven at less than 0.03% THD.IM Distortion (SMPTE)80 Watts into 6 Ohms 0.03 %80 Watts into 4 Ohms 0.03 %IM Distortion (CCIF, Any Combination from 1kHz to 20kHz)80 Watts into 6 Ohms 0.03 %80 Watts into 4 Ohms30Dynamic Headroom into 6 Ohms1.6dBOMC Activation10mV rms12V Trigger Input Voltage Range10.0V to 20.0V DC, 100k Ohms12V Trigger Output Current25 5mA, 470 OhmsInput Impedance25k OhmsInput Sensitivity80 Watt into 6 Ohms1V rms1 Watt into 6 Ohms114mV rmsDamping Factor 20Hz to 20kHz 31Rise Time5kHz, 50V peak-to-peak square wave,20% to 80%4 sPower Consumption (Continuous, All Channels Driven)Quiescent84/168VAMaximum960/1920VA80 Watts into 6 Ohms744/1488VA80 Watts into 4 Ohms900/1800VAGENERALPower (available in 240V)120VAC/50-60HzAmbient Operating Temperature 100 F (40 C)Operating Temperature68 F (20 C)above ambient temperatureVentilation Air Flow150 cubic feet/minute maximumNet Chassis Dimensions17.2x5.3x17.8 inches (437x133x451 mm)or 3 rack heightsMaximum Gross Dimensions18.9x19.0 x5.7 inches (480.1x481.7x144.8 mm)(includes rack mounting hardware,feet and speaker terminals)Weight CI 9060, Packed58 lb (26.4 Kg), 68 lb (31 Kg)Weight CI 9120, Packed80 lb (36.5 Kg), 90 lb (41 Kg)4+15V-15V+15VA-15VAR-INL-ININ5IN3IN1IN6IN2IN4IN5IN2IN4IN6IN1IN3-15V+15V+15VA-15VA-15VA+15VA1C80.1uF1Q22SC1815GR121RCA8RCA JACK1R2910 (C Version)121RCA1*RCA JACK121RCA6RCA JACK1R1100KCW3121RV320K1R2610 (C Version)121RCA9RCA JACK1R2100K13284U1AOPA21341R3210 (C Version)1R274.99K1R19220K1Q62SC1815GR1R4*1 (C Version)1R21220KCW3121RV220K1R17220K1R8*1 (C Version)CW3121RV620K+121C64.7uF 10V1C110.1uF121RCA11RCA JACKCW3121RV120K121RCA14RCA JACK1R351 (C Version)121RCA3*RCA JACK1R15220K1C100.1uF1Q42SC1815GR1R13220K1D31N41481D41N4148756U1BOPA21341D11N4148+121C44.7uF 10V1R374.99K13284U2AOPA21341D21N41481R334.99K121RCA13RCA JACK121RCA16RCA JACK1C120.1uF1R244.99K+121C74.7uF 10V12345671P47PIN1R314.99K1R344.99K121RCA4RCA JACK1Q52SC1815GRCW3121RV420K756U2BOPA21341C210pF121RCA15RCA JACK1R5100K1R364.99K121RCA10RCA JACK1R12100KCW3121RV520K121RCA5RCA JACK+121C54.7uF 10V121RCA7RCA JACK1R2230M1R9100K1R284.99K1C130.1uF1R3810K1Q32SC1815GR1R20220K1Q12SC1815GR121RCA2RCA JACK1R1410 (C Version)1R775.01R304.99K+121C34.7uF 10V1R184.99K121RCA12RCA JACK+121C14.7uF 10V1R164.99K1R1175.01R6100K1R375.01R2310 (C Version)1R254.99K1R10100KFlexPadNOTE:Six RCA Jumpers are provided for eachFlexPad that is installed in a chassis. ForMono operation, an RCA Jumper is installedon the rear panel from J5 to J6, another fromJ7 to J8, another from J9 to J10, anotherfrom J11 to J12, another from J13 to J14,and the last from J15 to J16. J17 is notneeded, and omitting it prevents the userfrom continuing the daisy-chain onto thesecond FlexPad, if installed.Components with the * mark are notinserted in CI9120s second Flexpad.1234561P16PIN1234561P26PIN1Q7*2SC1815GR1D7*1N41481R39*1M+15VA121P3*2PIN1D51N41481D61N41481R412201R521001R402201C14470p1R432201R531001C18470p1R512201R571001C17470p1R492201R561001C16470p1R472201R551001C15470P1R452201R541001C19470p1R422201R442201R462201R482201R50220-15V-15V-15V-15V-15V-15V+15V+15V+15V+15V+15V+15V1R621001R611001R601001R591001R581001R63100AmpInput2AmpInput3AmpInput1AmpInput4AmpInput5L-INR-INAmpInput6AmpInput1AmpInput2AmpInput3AmpInput4AmpInput5AmpInput6INPUT-SENCEINPUT-SENCEIn SenceIn SenceTo Mother Board 4P7 or Slave Mother board 5P7To a Trigger Board 9P4To 2nd or 4th Amp Module 2P3To 1st or 3rd Amp Module 2P3CH1 or CH7INCH1 or CH7INININININOUTOUTOUTOUTOUTCH2 or CH8CH2 or CH8CH3 OR CH9CH5 or CH11CH6 or CH12CH3 or CH9CH4 or CH10CH4 or CH10CH5 or CH111C20*0.1uF1R6410/1W1C2133uF1C2233uF1C2333uF1C2433uF1C2533uF1C2633uF1R7047k1R6947k1R6847k1R6747k1R6647k1R6547k1C2910uF1C3010uF1C3210uF1C2810uF1C2710uF1C3110uF+15V-15V12341P54PINR-INL-INNote:IN CI9060, 1P5 IS NOT INSERTTo Another Flex-pad Board 1P51C330.1uFINPUT-SENCETEXTE C B2SC1815GR12348765OPA2134OUT A-IN A+IN AV-+IN B-IN BOUT BV+FlexPadTMC 2000 NAD Electronics International, a division of Lenbrook Industries LimitedATO LogicTMC 2000 NAD Electronics International, a division of Lenbrook Industries LimitedSleep/Wake+121C933uF3.3 (AH Version)3.3 (AH Version)3.3 (AH Version)3.3 (AH Version)3.3 (AH Version)3.3 (AH Version)3.3 (AH Version)3.3 (AH Version)512345CI9120 AC INPLUG2T3StandbyTransformerFUSE HOLDER20AT1Main TransformerT2Main Transformer123451233PINJV1V12JAJV2V12JA1239P33PIN129P42PINFAN1FANFAN2FANFAN3FAN12W282PIN12W272PIN12W262PINSW2SPDTSW1SPDT129P22PIN122PINTo Mother Board 4P1To Flexpad 1P3Trigger And Switch BoardNote:In CI9120, Use 3 fansIn CI9060, Use 2 fans, omit FAN3To Mother Board 4P65RT10.1 5W5RT20.1 5W5RT30.1 5W5RT40.1 5W5RT50.1 5W5RT60.1 5W5PO1speaker terminal5PO2speaker terminal5PO3speaker terminal5PO4speaker terminal5PO6speaker terminal5PO5speaker terminalRETURN1RETURN2RETURN3RETURN4RETURN5RETURN6OUTPUT1OUTPUT2OUTPUT3OUTPUT4OUTPUT5OUTPUT65D21.5A5C3680uF 35V5C15680uF 35V5C24.7uF 50V5C134.7uF 50V213IN5U2LM7915123IN5U1LM78155C80.1uF5C120.1uFAC1AC2+15V-15V123456789105P1010PIN123456789105P1110PIN+15V-15V12345675P77PIN+15V-15V+15VA-15VA12345675P206PIN12345675P217PIN+35V2+35V2-35V2-35V2OUTPUT6OUTPUT5OUTPUT4+15V-15VOUTPUT3OUTPUT2OUTPUT11234565P126PIN-15VA+15VAOMC-SENSETEMP-SENSETEMP PRO+35V2-35V25M11PIN5M21PIN5

    注意事项

    本文(NAD-CI9060-pwr-sm 维修电路原理图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2025 收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开