JVC-DD8E-nms-sm 维修电路原理图.pdf
SERVICE MANUALCOPYRIGHT 2006 Victor Company of Japan, LimitedNo.MB5632006/11NETWORK MEDIA SYSTEMMB563200611DD-8B,DD-8E,DD-8EN,DD-8EV,DD-8EE,DD-3B,DD-3E,DD-3EN,DD-3EV,DD-3EELead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-42SPECIFIC SERVICE INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-83DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-94ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-325TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-35(Only for DD-8 and DD-3)CA-DD8SP-DD8FSP-DD8FSP-PWDD8SP-DD8SCA-DD3SP-DD3FSP-DD3F SP-PWDD3SP-DD8SRadioFans.CN 收音机爱 好者资料库1-2 (No.MB563)SPECIFICATIONMain unit (CA-DD8/CA-DD3)Subwoofer for DD-8 (SP-PWDD8)TunerFM frequency : 87.50 MHz - 108.00 MHzAM frequency : 522 kHz - 1 629 kHzTerminal (front of the main unit)Audio output headphone terminal 1Impedance : 16 to 1 kUSB digital input terminal 1Analog input terminal 1Stereo mini jackAnalog output terminal 1Stereo mini jackTerminal (rear of the main unit)Optical digital input terminal 1-23 dBm to -15 dBmOptical digital output terminal 1-23 dBm to -15 dBmSystem terminal 1Component video output terminals (3) 1Y : 1.0 Vp-p, sync negative, 75 terminatedPB : 0.7 Vp-p, 75 terminatedPR : 0.7 Vp-p, 75 terminatedAudio input terminals (2) 1500 mV/47 kSCART terminal 1AM antenna terminal 1FM antenna terminal 1Ethernet terminalHDMI monitor output terminalUSBCompatible with USB 2.0 Full-SpeedCompatible device : Mass storage class deviceCompatible file system : FAT16, FAT32Bus power supply : Max. 500 mAGeneralPower source : AC 230 V , 50 HzPower consumption (in operation) : 25 WPower consumption (on standby) : 0.5 WDimensions (W H D) : 445 mm 55 mm 286.4 mm (including projecting parts)Weight : 3.5 kg (CA-DD8), 3.0 kg (CA-DD3)TypeBass reflex type, Magnetically shielded typeAmplifierSubwoofer : 120 W at 4 (110 Hz, THD 10%)Left/right speaker : 25 W 2 at 3 (1 kHz, THD 10%)Center surround speaker : 25 W 2 at 3 (1 kHz, THD 10%)Speaker16 cm conePower handling capacity : 120 WImpedance : 4 Frequency range : 30 Hz - 230 HzSound pressure level : 72 dB/WmGeneralPower source : AC 230 V , 50 HzPower consumption : 120 WDimensions (W H D) : 242 mm 364 mm 363 mmWeight : 12.6 kgRadioFans.CN 收音机爱 好者资料库(No.MB563)1-3Subwoofer for DD-3 (SP-PWDD3)Left and right speakers forDD-8 (SP-DD8F)Left and right speakers forDD-3 (SP-DD3F)Center surround speaker for DD-8/DD-3 (SP-DD8S)Designs and specifications are subject to change without notice.TypeBass reflex typeAmplifierSubwoofer : 120 W at 4 (110 Hz, THD 10%)Left/right speaker : 25 W 2 at 3 (1 kHz, THD 10%)Center surround speaker : 25 W 2 at 3 (1 kHz, THD 10%)Speaker16 cm conePower handling capacity : 120 WImpedance : 4 Frequency range : 30 Hz - 230 HzSound pressure level : 72 dB/WmGeneralPower source : AC 230 V , 50 HzPower consumption : 120 WDimensions (W H D) : 242 mm 364 mm 363 mmWeight : 12.3 kgType2-way 3-speaker bass reflex type, Magnetically shielded typeSpeaker8 cm cone 2 + 2 cm domePower handling capacity30 WImpedance3 Frequency range60 Hz - 40 kHzSound pressure level81 dB/WmDimensions (W H D)289 mm 1 101 mm 289 mmWeight (1 unit)10.0 kgType2-way acoustic suspension type, Magnetically shielded typeSpeaker9.5 cm 1 cm direct drive + 2 cm domePower handling capacity30 WImpedance3 Frequency range100 Hz - 40 kHzSound pressure level78 dB/WmDimensions (W H D)165 mm 376 mm 165 mm (including stand)Weight (1 unit)1.0 kg (including stand)Type1-way acoustic suspension type, Magnetically shielded typeSpeaker9.5 cm 1 cm direct-drivePower handling capacity30 WImpedance3 Frequency range120 Hz - 40 kHzSound pressure level79 dB/WmDimensions (W H D)344 mm 61 mm 76 mm (including stand)Weight0.95 kg (including stand)1-4 (No.MB563)SECTION 1PRECAUTION1.1Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using aLeakage Current Tester, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE(No.MB563)1-51.5 Safety Precautions (U.K only)(1) This design of this product contains special hardware and many circuits and components specially for safety purposes. For con-tinued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replace-ment parts must be identical to those used in the original circuits.(2) Any unauthorised design alterations or additions will void the manufacturers guarantee; furthermore the manufacturer cannotaccept responsibility for personal injury or property damage resulting therefrom.(3) Essential safety critical components are identified by ( ) on the Parts List and by shading on the schematics, and must neverbe replaced by parts other than those listed in the manual. Please note however that many electrical and mechanical parts inthe product have special safety related characteristics. These characteristics are often not evident from visual inspection. Partsother than specified by the manufacturer may not have the same safety characteristics as the recommended replacement partsshown in the Parts List of the Service Manual and may create shock, fire, or other hazards.(4) The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts,high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service isrequired, the original lead routing and dress should be observed, and it should be confirmed that they have been returned tonormal, after re-assembling.1.5.1Warning(1) Service should be performed by qualified personnel only.(2) This equipment has been designed and manufactured to meet international safety standards.(3) It is the legal responsibility of the repairer to ensure that these safety standards are maintained.(4) Repairs must be made in accordance with the relevant safety standards.(5) It is essential that safety critical components are replaced by approved parts.(6) If mains voltage selector is provided, check setting for local voltage.Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of preforming repair of this system.1-6 (No.MB563)1.6Preventing static electricityElectrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laserdiode in the traverse unit (optical pickup). Take care to prevent this when performing repairs.1.6.1 Grounding to prevent damage by static electricityStatic electricity in the work area can destroy the optical pickup (laser diode) in devices such as laser products. Be careful to use proper grounding in the area where repairs are being performed. (1) Ground the workbenchGround the workbench by laying conductive material (such as a conductive sheet) or an iron plate over it before placing thetraverse unit (optical pickup) on it.(2) Ground yourselfUse an anti-static wrist strap to release any static electricity built up in your body. (3) Handling the optical pickup In order to maintain quality during transport and before installation, both sides of the laser diode on the replacement opticalpickup are shorted. After replacement, return the shorted parts to their original condition. (Refer to the text.) Do not use a tester to check the condition of the laser diode in the optical pickup. The testers internal power source can easilydestroy the laser diode. 1.7Handling the traverse unit (optical pickup)(1) Do not subject the traverse unit (optical pickup) to strong shocks, as it is a sensitive, complex unit. (2) Cut off the shorted part of the flexible cable using nippers, etc. after replacing the optical pickup. For specific details, refer to thereplacement procedure in the text. Remove the anti-static pin when replacing the traverse unit. Be careful not to take too long atime when attaching it to the connector. (3) Handle the flexible cable carefully as it may break when subjected to strong force. (4) I t is not possible to adjust the semi-fixed resistor that adjusts the laser power. Do not turn it.1.8Attention when traverse unit is decomposed*Please refer to Disassembly method in the text for the pickup unit. Apply solder to the short land sections before the card wire is disconnected from the connecto on the servo board. (If the card wireis disconnected without applying solder, the pickup may be destroyed by static electricity.) In the assembly, be sure to remove solder from the short land sections after connecting the card wire.1MConductive material(conductive sheet) or iron palate(caption)Anti-static wrist strapSolder short land section(No.MB563)1-71.9Important for laser products1.CLASS 1 LASER PRODUCT 2.CAUTION : Visible and/or invisible class 1M laser radiation when open. Do not view directly with optical instruments. 3.CAUTION : Visible and/or invisible laser radiation when open and inter lock failed or defeated. Avoid direct exposure to beam.4.CAUTION : This laser product uses visible and/or invisible laser radiation and is equipped with safety switches which prevent emission of radiation when the drawer is open and the safety interlocks have failed or are defeated. It is dangerous to defeat the safety switches.5.CAUTION : If safety switches malfunction, the laser is able to function. 6.CAUTION : Use of controls, adjustments or performance of procedures other than those specified here in may result in hazardous radiation exposure. REPRODUCTION AND POSITION OF LABELS and PRINT!Please use enough caution not to see the beam directly or touch it in case of an adjustment or operationcheck. WARNING LABEL and PRINT1-8 (No.MB563)SECTION 2SPECIFIC SERVICE INSTRUCTIONSThis service manual does not describe SPECIFIC SERVICE INSTRUCTIONS.(No.MB563)1-9SECTION 3DISASSEMBLY3.1Main body section3.1.1Removing the side panel L, R (See Fig.1)(1) From the bottom sides of the main body, remove the fourscrews A attaching the side panel L and side panel R.(2) Remove the side panel L and side panel R.Fig.1Side panel RSide panel LAA1-10 (No.MB563)3.1.2Removing the top cover (See Figs. 2 to 9) Remove the side panel L and side panel R.(1) From the left and right side of the main b