欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 国外收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 功放/音响/收扩>
  • 老电视>
  • ImageVerifierCode 换一换

    Marantz-SR7005-avr-sm 维修电路原理图.pdf

    • 资源ID:147764       资源大小:22.52MB        全文页数:205页
    • 资源格式: PDF        下载积分:35积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    Marantz-SR7005-avr-sm 维修电路原理图.pdf

    ServiceManual Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referring to the operating instructions without fail. For purposes of improvement, specifi cations and design are subject to change without notice.AV Surround ReceiverSR7005 /N1SG/N1B/U1B/K1BsSR7005SR7005S00114-1V02DM/DG1009Copyright 2010 D&M Holdings Inc. All rights reserved.WARNING: Violators will be prosecuted to the maximum extent possible.Ver. 2Please refer to the MODIFICATION NOTICE.2MARANTZ DESIGN AND SERVICEUsing superior design and selected high grade components, MARANTZ company has created the ultimate in stereo sound.Only original MARANTZ parts can insure that your MARANTZ product will continue to perform to the specifi cations for which it is famous. Parts for your MARANTZ equipment are generally available to our National Marantz Subsidiary or Agent. ORDERING PARTS : Parts can be ordered either by mail or by Fax. In both cases, the correct part number has to be specifi ed. The following information must be supplied to eliminate delays in processing your order : 1. Complete address 2. Complete part numbers and quantities required 3. Description of parts 4. Model number for which part is required 5. Way of shipment 6. Signature : any order form or Fax. must be signed, otherwise such part order will be considered as null and void.In case of diffi culties, do not hesitate to contact the Technical Department at above mentioned address. 091105DM/DGUSAMARANTZ AMERICA, INC100 CORPORATE DRIVEMAHWAH, NEW JERSEY 07430USAEUROPE / TRADING D&M EUROPE B. V. P. O. BOX 8744, BUILDING SILVERPOINTBEEMDSTRAAT 11, 5653 MA EINDHOVENTHE NETHERLANDSPHONE : +31 - 40 - 2507844FAX : +31 - 40 - 2507860KOREAD&M SALES AND MARKETING KOREA LTD.2F,YEON BLDG.,88-5, BANPO-DONG, SEOCHO-GU,SEOUL KOREAPHONE : +82 - 2 - 715 - 9041FAX : +82 - 2 - 715 - 9040CANADAD&M Canada Inc.5-505 APPLE CREEK BLVD. MARKHAM, ONTARIO L3R 5B1CANADAPHONE : 905 - 415 - 9292FAX : 905 - 475 - 4159JAPAND&M BUILDING, 2-1 NISSHIN-CHO,KAWASAKI-KU, KAWASAKI-SHI,KANAGAWA, 210-8569 JAPAND&M Holdings Inc.CHINAD&M SALES AND MARKETING SHANGHAI LTD.ROOM.808 SHANGHAI AIRPORT CITY TERMINAL NO.1600 NANJING (WEST) ROAD, SHANGHAI, CHINA. 200040TEL : 021 - 6248 - 5151FAX : 021 - 6248 - 4434SHOCK, FIRE HAZARD SERVICE TEST : CAUTION : After servicing this appliance and prior to returning to customer, measure the resistance between either primary AC cord connector pins (with unit NOT connected to AC mains and its Power switch ON), and the face or Front Panel of product and controls and chassis bottom. Any resistance measurement less than 1 Megohms should cause unit to be repaired or corrected before AC power is applied, and verifi ed before it is return to the user/customer. Ref. UL Standard No. 60065.NOTE ON SAFETY :Symbol z Fire or electrical shock hazard. Only original parts should be used to replaced any part marked with symbol z . Any other component substitution (other than original type), may increase risk of fi re or electrical shock hazard.安全上注意:z部品、安全上重要部品。必指定部品番号部品使用下。3SAFETY PRECAUTIONSThe following check should be performed for the continued protection of the customer and service technician.LEAKAGE CURRENT CHECKBefore returning the unit to the customer, make sure you make either (1) a leakage current check or (2) a line to chassis resistance check. if the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the unit is defective.Be sure to test for leakage current with the AC plug in both polarities, in addition, in each power ON, OFF and STANDBY mode, if applicable.CAUTION Please heed the points listed below during servicing and inspection. Heed the cautions!Spots requiring particular attention when servicing, such as the cabinet, parts, chassis,etc., have cautions indicated on labels. be sure to heed these causions and the cautions indicated in the handling instructions. Caution concerning electric shock!(1) An AC voltage is impressed on this set, so touching internal metal parts when the set is energized could cause electric shock. Take care to avoid electric shock, by for example using an isolating transformer and gloves when servicing while the set is energized, unplugging the power cord when replacing parts, etc.(2) Tere are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly!Through great care is taken when manufacturing parts from sheet metal, there may in some rare cases be burrs on the edges of parts which could cause injury if fi ngers are moved across them. Use gloves to protect your hands. Only use designated parts!The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). For replacement parts, be sure to use parts which have the same poroperties. In particular, for the important safety parts that are marked z on wiring diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were originally!For safety seasons, some parts use tape, tubes or other insulating materials, and some parts are mounted away from the surface of printed circuit boards. Care is also taken with the positions of the wores omsode amd clamps are used to keep wires away from heating and high voltage parts, so be sure to set everything back as it was originally. Inspect for safety after servicing!Check that all screws, parts and wires removed or disconnected for servicing have been put back in their original positions, inspect that no parts around the area that has been serviced have been negatively affected, conduct an inslation check on the external metal connectors and between the blades of the power plug, and otherwise check that safety is ensured.(Insulation check procedure)Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and turn the power switch on. Using a 500V insulation resistance tester, check that the inplug and the externally exposed metal parts (antenna terminal, headphones terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired.Many of the electric and structural parts used in the set have special safety properties. In most cases these properties are difficult to distinguish by sight, and using replacement parts with higher ratings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be poreserved. Parts with safety properties are indicated as shown below on the wiring diagrams and parts lists is this service manual. Be sure to replace them with parts with the designated part number.(1) Schematic diagrams .Indicated by the z mark.(2) Parts lists .Indicated by the z mark.Using parts other than the designated parts could result in electric shock, fi res or other dangerous situations.CAUTION Concerning important safety parts4NOTE FOR SCHEMATIC DIAGRAMWARNING:Parts marked with this symbol z have critical characteristics. Use ONLY replacement parts recommended by the manufacturer.CAUTION:Before returning the unit to the customer, make sure you make either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the unit is defective.WARNING:DO NOT return the unit to the customer until the problem is located and corrected.NOTICE:ALL RESISTANCE VALUES IN OHM. k=1,000 OHM / M=1,000,000 OHMALL CAPACITANCE VALUES IN MICRO FARAD. P=MICRO-MICRO FARAD EACH VOLTAGE AND CURRENT ARE MEASURED AT NO SIGNAL INPUT CONDITION. CIRCUIT AND PARTS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE.Parts for which nsp is indicated on this table cannot be supplied.When ordering of part, clearly indicate 1 and I (i) to avoid mis-supplying.Ordering part without stating its part number can not be supplied. Not including General-purpose Carbon Chip Resistor in the P.W.Board parts list. (Refer to the Schematic Diagram for those parts.)Parts marked with this symbol z have critical characteristics. Use ONLY replacement parts recommended by the manufacturer.Not including General-purpose Carbon Film Resistor in the P.W.Board parts list. (Refer to the Schematic Diagram for those parts.)Part indicated with the mark is not illustrated in the exploded view.WARNING:1.2.3.4.5.6.ResistorsRD:CarbonRC:CompositionRS :Metal oxide filmRW:windingRN:Metal filmRK :Metal mixtureP:Pulse-resistant typeNL :Low noise typeNB :Non-burning typeFR :Fuse-resistorF:Lead wire forming2B :1/8 W2E :1/4 W2H :1/2 W3A :1 W3D :2 W3F :3 W3H :5 WF:1%G:2%J:5%K:10%M :20%Ex.:RNType14KShapeand per-formance2EPower182Resist-anceGAllowableerrorFROthers* Resistance1800ohm=1.8kohm1 82Indicates number of zeros after effective number.2-digit effective number.1.2ohm1 R22-digit effective number, decimal point indicated by R.1-digit effective number.: Units: ohmCapacitorsCE :Aluminum foilelectrolyticCA :Aluminium solidelectrolyticCS :Tantalum electrolyticCQ:FilmCK :CeramicCC:CeramicCP :OilCM:MicaCF :MetallizedCH:MetallizedHS :High stability typeBP :Non-polar typeHR:Ripple-resistant typeDL :For change and dischargeHF :For assuring high requencyU:UL partC:CSA partW :UL-CSA partF:Lead wire forming0J :6.3 V1A :10 V1C :16 V1E :25 V1V :35 V1H :50 V2A :100 V2B :125 V2C :160 V2D :200 V2E :250 V2H :500 V2J :630 VF:1%G:2%J:5%K:10%M :20%Z:80%:- 20%P:+100%C:0.25pFD:0.5pF=:OthersEx.:CEType04WShapeand per-formance1HDielectricstrength3R2CapacityMAllowableerrorBPOthers Units:F.2200F2 22Indicates number of zeros after effective number.2-digit effective number. Units:F.2.2F2 R22-digit effective number, decimal point indicated by R1-digit effective number.*Capacity (electrolyte only)When the dielectric strength is indicated in AC,AC is included after the dieelectric strength value.*Capacity (except electrolyte) Units:pF2200pF=0.0022F2 22Indicates number of zeros after efective number. (More than 2)2-digit effective number. Units:pF220pF2 212-digit effective number.Indicates number of zeros after effective numver. (0 or 1)NOTE FOR PARTS LIST5TECHNICAL SPECIFICATIONS n Audio Section Power amplifi erRated output :Front :125 W + 125 W (8 , 20 Hz 20 kHz with 0.08 % T.H.D.)Center :125 W (8 , 20 Hz 20 kHz with 0.08 % T.H.D.)Surround :125 W + 125 W (8 , 20 Hz 20 kHz with 0.08 % T.H.D.)Surround back / Front height / Front wide:125 W + 125 W (8 , 20 Hz 20 kHz with 0.08 % T.H.D.)Maximum effective output power :Front :195 W + 195 W (6 , 1 kHz with 10 % T.H.D.)Center :195 W (6 , 1 kHz with 10 % T.H.D.)Surround :195 W + 195 W (6 , 1 kHz with 10 % T.H.D.)Surround back / Front height / Front wide:195 W + 195 W (6 , 1 kHz with 10 % T.H.D.)Output connectors : 6 8 AnalogInput sensitivity/Input impedance : 200 mV/47 kFrequency response : 10 Hz 100 kHz +1, 3 dB (DIRECT mode) S/N : 96 dB (IHFA weighted, DIRECT mode)Distortion : 0.008 % (20 Hz 20 kHz) (DIRECT mode)Rated output : 1.2 V DigitalD/A output : Rated output 2 V (at 0 dB playback) Total harmonic distortion 0.008 % (1 kHz, at 0 dB) S/N ratio 102 dB Dynamic range 100 dBDigital input : Format Digital audio interface Phono equalizer (PHONO input REC OUT)Input sensitivity : 2.5 mVRIAA deviation : 1 dB (20 Hz to 20 kHz) S/N : 96 dB (IHFA weighted, DIRECT mode)Distortion : 74 dB (A weighting, with 5 mV input)Rated output : 150 mVDistortion factor : 0.03 % (1 kHz, 3 V) n Video Section Standard video connectorsInput/output level and impedance : 1 Vp-p, 75 Frequency response : 5 Hz 10 MHz +1, 3 dB Color component video connectorInput/output level and impedance:Y (brightness) signal 1 Vp-p, 75 PB / CB signal 0.7 Vp-p, 75 PR / CR signal 0.7 Vp-p, 75 Frequency response :5 Hz 60 MHz +0, 3 dB (when “Video Convert” set to “OFF”) n HD Radio section (for U)FM(Note: V at 75 , 0 dBf = 1 x 1015 W)Receiving Range :FM 87.5 MHz 107.9 MHz AM530 kHz 1710 kHzUsable Sensitivity :FM1.5 V (14.8 dBf) AM18 VS/N (IHF-A) :FMMONO 78 dB AMSTEREO 68 dBHD 85 dB 85 dBTotal harmonic Distortion (at 1 kHz) :FMMONO 0.1 % AMSTEREO 0.1 %HD 0.02 % 0.02 % n Tuner section (for N, K) sFM(Note: V at 75 , 0 dBf = 1 x 1015 W)Receiving Range : FM 87.5 MHz 108.0 MHz AM522 kHz 1611 kHzUsable Sensitivity :FM1.2 V (12.8 dBf) AM18 V50 dB Quieting Sensitivity :FMMONO 2.0 V (17.3 dBf)STEREO 42 V (34.5 dBf)S/N (IHF-A) :FMMONO 72 dBSTEREO 67 dBTotal harmonic Distortion (at 1 kHz) :FMMONO 0.3 %STEREO 0.7 % n GeneralPower supply (for U) : AC 120 V, 60 HzPower supply (for N) : AC 230 V, 50 Hz Power supply (for K) : AC 220 V, 50 Hz sPower consumption :700 W0.2 W (Standby)4.0 W (CEC standby)Maximum external dimensions : 440 (W) x 187 (H) x 406 (D) mmWeight : 13.0 kg n Remote Control Unit (RC011SR)Batteries : R03/AAA Type (two batteries)625752.729.840.716.5170.518742326752.723.522.5360406100340440DIMENSION s7CAUTION IN SERVICINGFirmware update s When you replace the DIGITAL UNIT ASSY (8U-310051), you need software updates. Refer to VERSION UPGRADE PROCEDURE OF FIRMWARE (27 - 37 page) .Please update the following procedure.1. First, Please update by DFW (34 - 37 page).2. Next, Please update the latest fi rmware by DPMS (27 - 33 page).Initializing AV SURROUND RECEIVERAV SURROUND RECEIVER initialization should be performed when the com, peripheral parts of com, and Digital P.W.B. are replaced.1. Turn off the power using ON/STANDBY button.2. Press ON/STANDBY button while simultaneously pressing SURROUND MODE and AUTO buttons.3. Check that the entire display is fl ashing with an interval of about 1 second, and release your fi ngers from the 2 buttons and the microprocessor will be initialized.Service Jigs When you repair the printing board, you can use the following JIG (Extension cable kit). Please order to marantz Offi cial Service Distributor in your region if necessary.8U-110084S : EXTENSION UNIT KIT : 1 Set(Refer to JIG FOR SERVICING.)Note: If step 3 does not work, start over from step 1. All user settings will be lost and this factory setting will be recovered when this initialization mode. So make sure to memorize your setting for restoring after the initialization.ON/STANDBYSURROUND MODEAUTO8DISASSEMBLY Disassemble in order of the arrow of the fi gure of following fl ow. In the case of the re-assembling, assemble it in order of the reverse of the following fl ow. In the case of the re-assembling, observe attention of assembling it. If wire bundles are untied or moved to perform adjustment or parts replacement etc., be sure to rearrange them neatly as they were originally bundled or placed afterward.Otherwise, incorrect arrangement can be a cause of noise generation.FRONT PANEL ASSYRefer to DISASSEMBLY 1. FRONT PANEL ASSYand EXPLODED VIEWFRONT UNIT ASSY(Ref. No. of EXPLODED VIEW : P1)OPT UNIT(Ref. No. of EXPLODED VIEW : P2)H/P UNIT(Ref. No. of EXPLODED VIEW : P3)FRONT HDMI UNIT(Ref. No. of EXPLODED VIEW : P4)DOORDET UNIT(Ref. No. of EXPLODED VIEW : P5)TRANS MAINRefer t

    注意事项

    本文(Marantz-SR7005-avr-sm 维修电路原理图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2025 收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开