欢迎来到收音机爱好者资料库! | 帮助中心 忘不了收音机那份情怀!
收音机爱好者资料库
全部分类
  • 德国收音机>
  • 国产收音机>
  • 日本收音机>
  • 国外收音机>
  • 进口随身听>
  • 卡座/开盘/组合/收录机>
  • CD/VCD/DVD/MD/DAC>
  • DAT/LP唱机>
  • 功放/音响/收扩>
  • 老电视>
  • ImageVerifierCode 换一换

    GrundigUMS200 维修电路图、原理图.pdf

    • 资源ID:110362       资源大小:5.58MB        全文页数:36页
    • 资源格式: PDF        下载积分:22积分
    会员登录下载
    三方登录下载: QQ登录
    账号:
    密码:
    验证码:   换一换
      忘记密码?
        
    友情提示
    2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
    3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
    4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
    5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。

    GrundigUMS200 维修电路图、原理图.pdf

    UMS 200 GLK0850 Zustzlich erforderliche Unterlagen fr den Komplettservice Additionally required Service Documents for the Complete Service Service Manual Grundig Service Hotline Deutschland TV TV SAT VCR/LiveCam HiFi/Audio Car Audio Telekommunikation Fax: Planatron (8.00-22.00 Uhr) 0180/52318-41 0180/52318-49 0180/52318-48 0180/52318-42 0180/52318-43 0180/52318-44 0180/52318-45 0180/52318-51 0180/52318-99 Mo.-Fr. 8.00-18.00 Uhr Telefon:0180/52318-40 0180/52318-50Fax: Technik: Ersatzteil-Verkauf:Mo.-Fr. 8.00-19.00 Uhr Kundendienst/Werksttten: 0180/52318-52 0180/52318-46 Telefon: Fax: gebhrenpflichtig Mo.-Fr. 8.00-18.00 Uhr Sicherheit Safety Materialnr./Part No. 720108000000 HiFiService Manual Materialnummer/Part Number 720107717500 nderungen vorbehalten/Subject to alteration Printed in Germany W E-BS-SA16 0901 8002/8012, 8005/8015, 8006/8016 Allgemeiner Teil / General SectionUMS 200 1 - 2GRUNDIG Service Es gelten die Vorschriften und Sicherheitshin- weise gem dem Service Manual Sicherheit, Materialnummer 720108000000, sowie zustz- lich die eventuell abweichenden, landes- spezifischen Vorschriften! The regulations and safety instructions shall be valid as provided by the Safety Service Manual, part number 720108000000, as well as the re- spective national deviations! Table of Contents Page General Section. 1 - 2 1 - 17 Measuring Instruments / Equipment . 1 - 2 Technical Data . 1 - 3 Service Hints . 1 - 3 Disassembly Instructions . 1 - 5 Operations of the CD Mechanism . 1 - 11 Operating Hints . 1 - 15 Adjustment Procedures.2 - 4 . 2 - 6 Tuner. 2 - 4 Cassette . 2 - 5 CD . 2 - 6 Layout of PCBs and Circuit Diagrams . 3 - 1 3 - 19 Wiring Diagram . 3 - 1 Circuit Diagrams: Power Supply Board . 3 - 2 Main Board - Circuit Diagram AF and Amplifier . 3 - 4 Main Board - Circuit Diagram Tuner Part . 3 - 6 Main Board - Circuit Diagram CD Part . 3 - 8 Operating Board . 3 - 12 Cassette Board . 3 - 16 CD Mechanism. 3 - 19 Layout of the PCBs: Power Supply Board . 3 - 2 Main Board . 3 - 10 Operating Board . 3 - 14 Cassette Board . 3 - 18 CD Interface . 3 - 19 Exploded Views and Spare Parts List. 4 - 1 4 - 4 Inhaltsverzeichnis Seite Allgemeiner Teil . 1 - 2 1 - 15 Messgerte / Messmittel . 1 - 2 Technische Daten . 1 - 3 Servicehinweise . 1 - 3 Ausbauhinweise . 1 - 5 Funktionsbeschreibung CD-Laufwerk . 1 - 11 Bedienhinweise . 1 - 13 Abgleichvorschriften .2 - 1 . 2 - 3 Tuner. 2 - 1 Cassette . 2 - 2 CD . 2 - 3 Platinenabbildungen und Schaltplne . 3 - 1 3 - 19 Verdrahtungsplan. 3 - 1 Schaltplne: Netzteil-Platte . 3 - 2 Haupt-Platte - Schaltplanteil NF und Verstrker . 3 - 4 Haupt-Platte - Schaltplanteil Tuner . 3 - 6 Haupt-Platte - Schaltplanteil CD . 3 - 8 Bedien-Platte. 3 - 12 Cassetten-Platte. 3 - 16 CD-Laufwerk . 3 - 19 Platinenabbildungen: Netzteil-Platte . 3 - 2 Haupt-Platte . 3 - 10 Bedien-Platte. 3 - 14 Cassetten-Platte. 3 - 18 CD-Interface . 3 - 19 Explosionszeichnungen und Ersatzteilliste . 4 - 1 4 - 4 Allgemeiner Teil Messgerte / Messmittel FrequenzzhlerMess-Sender WobbelsenderOszilloskop DigitalvoltmeterTest-CD Testcassette 3150Hz/10kHz (z.B. 448) Beachten Sie bitte das GRUNDIG Messtechnik-Programm, das Sie unter folgender Adresse erhalten: General Section Measuring Instruments / Equipment Frequency counterSignal generator Sweep generatorOscilloscope Digital voltmeterTest CD Test cassette 3150Hz/10kHz (e.g. 448) Please note the GRUNDIG Catalog Test and Measuring Equipment obtainable from: GRUNDIG AG Geschftsbereich Instruments Test- und Mess-Systeme Wrzburger Str. 150 D 90766 Frth/Bay Tel. 0911/703-4540 Fax 0911/703-4130 eMail: Internet: http:/www.grundig-instruments.de Internet: http:/www.grundig- UMS 200Allgemeiner Teil / General Section GRUNDIG Service1 - 3 Servicehinweise Vor ffnen des Gehuses Netzstecker ziehen. Cassettenteil berprfen Sie vor Beginn der Service-Arbeiten, ob die Magnetkpfe, die Tonwelle und die Gummiandruckrolle frei von Bandabrieb sind. Zum Reinigen dieser Teile verwenden Sie ein mit Spiritus oder Reinigungsbenzin getrnktes Wattestbchen; dadurch verbessert sich der Aufnahme- und Wiedergabepegel, sowie der Bandlauf. Nach dem Ersatz von Magnetkpfen oder sonstiger Bauteile mssen die technischen Daten des Gertes anhand der im Service Manual vorgegebenen Messwerte berprft bzw. eingestellt werden. Leitungsverlegung Bevor Sie die Leitungen und insbesondere die Masseleitungen lsen, muss die Leitungsverlegung zu den einzelnen Baugruppen beachtet werden. Nach erfolgter Reparatur ist es notwendig, die Leitungsfhrung wieder in den werkseitigen Zustand zu versetzen um evtl. sptere Ausflle oder Strungen zu vermeiden. Master Reset Gert vom Netz trennen. Taste TUNER gedrckt halten und Netzste- cker wieder einstecken. Im Display wird CLR ALL ? angezeigt. Durch Drcken der Taste STOP werden folgende Vorgnge ausge- lst: - alle FM/AM-Presets werden gelscht - automatischer Uhrabgleich - ein - Lautstrkeeinstellung - 25 - DSC - FLAT - BASS BOOST - aus - Mute - aus - Uhranzeige blinkt - Timer - aus - CD modes PROGRAM, RANDOM, REPEAT - aus - Cassettenteil - Grundeinstellung Wiedergabe - Standby - Display ein Service Hints Disconnect the mains plug before opening the set. Cassette Section Before commencing service work, ensure that the magnetic heads, the capstan and the pinch roller are free from particles produced by tape abrasion. The recording and playback levels and the tape run can be improved by cleaning these parts with a cotton-wool tip soaked in spirit or cleaning benzine. If the heads or other components have been replaced, the technical data of the recorder must be checked or adjusted according to the values specified in the Service Manual. Wiring Before disconnecting any leads and especially the earth connecting leads observe the way they are routed to the individual assemblies. On completion of the repairs the leads must be laid out as originally fitted at the factory to avoid later failures or disturbances. Master Reset Disconnect the set from the mains. Hold button TUNER depressed while connecting again to the mains. CLR ALL ? is shown in the display. Pressing button STOP will start following process: - all FM/AM presets are erased - automatic update of clock - on - volume setting - 25 - DSC - FLAT - BASS BOOST - off - Mute - off - clock time in display is blinking - Timer - off - CD modes PROGRAM, RANDOM, REPEAT - off - Cassette mode - Playback - Standby - display on Technische Daten Verstrkerteil Ausgangsleistung: Sinusleistung. 2 x 30W Musikleistung . 2 x 60W Eingangsempfindlichkeit/Impedanz . 400mV/22k Empfangsteil Empfangsbereich FM . 87,5 .108,0MHz Empfangsbereich MW. 522 . 1611kHz CD Teil Frequenzgang . 20Hz . 20kHz Geruschspannungsabstand: . (wtd.) 90dB Cassettenteil Tontrger . Compact-Cassette nach DIN 45516 (IECI) Frequenzbereich . 40Hz . 14,0kHz Spurlage.Viertelspur international Geruschspannungsabstand . (wtd.) 55dB Gleichlaufschwankungen . (WRMS) 0,15% Spannungsversorgung: Betriebsspannung . 230V Netzfrequenz. 50/60Hz max. Leistungsaufnahme . 170W Leistungsaufnahme in Standby. 90dB Cassette unit Sound recording medium . Compact tape according to DIN 45516 (IECI) Frequency range . 40Hz . 14.0kHz Tracking position . International quarter-track Noise voltage ratio . (wtd.) 55dB Wow and flutter . (WRMS) 0,15% Power supply Operating voltage. 230V Mains frequency. 50/60Hz Max. power consumption . 170W Power consumption in standby mode . 60dBV; Oszilloskop ber 100nF an Messpunkt A. AM, 522kHz; Digital-Voltmeter an Messpunkt B. AM; Mess-Sender ber Loop-Antennen ankoppeln; Ue 50dBV; fmod = 1kHz; Oszilloskop an Lautsprecher-Ausgang. FM; Mess-Sender mit exakter Frequenz an FM-Antennen- Eingang (alternativ: Rundfunksender). Digital-Voltmeter zwischen Messpunkte D und E. FM; Mess-Sender an FM-Antennen-Eingang; Ue = 50dBV; fmod = 19kHz; Oszilloskop an Lautsprecher-Ausgnge. Mit T105 a auf Maximum abglei- chen. Mit T103 b auf 1,7V 0,05V abgleichen. Wechselweise mit T101 c bei 603kHz und mit TC101 d bei 1404kHz auf NF-Maximum abgleichen. Mit T106 e auf 0V 0,04V abgleichen. Mit T107 g (linker Kanal) und mit T108 f (rechter Kanal) auf NF-Minimum abgleichen. a b c d e g f A ED B UMS 200Abgleichvorschriften / Adjustment Procedures GRUNDIG Service2 - 2 Cassette Messgerte: Frequenzzhler, Oszilloskop, Test-Cassette 3,15kHz/10kHz (z.B. 448) AbgleichVorbereitung Abgleichvorgang 1. Lsch-Oszillator 2. Vormagnetisierung 3. Azimut 4. Band- Geschwindigkeit Frequenzzhler an Messpunkt F. Leer-Cassette einlegen und Aufnahme starten. Leer-Cassette einlegen und Aufnahme starten. Rechter Kanal: Oszilloskop an Messpunkt L. Linker Kanal: Oszilloskop an Messpunkt M. Oszilloskop an Lautsprecher-Ausgang. Test-Cassette einlegen und 10kHz-Teil abspielen. Frequenzzhler an Lautsprecher-Ausgang. Test-Cassette einlegen und 3,15kHz-Teil abspielen. Mit T301 k auf 100kHz 5kHz abgleichen. Mit VR301 s auf 11Veff (31Vss) 0,5V abgleichen. Mit VR302 t auf 11Veff (31Vss) 0,5V abgleichen. Bei “TAPE “ mit Kopfschraube m auf maximalen und gleichen Pegel auf beiden Kanlen abgleichen. Bei “TAPE 60dBV; Oscilloscope via 100nF to Testpoint A. AM, 522kHz; Digital Voltmeter to Testpoint B. AM; Couple Signal Generator via Loop Antennas; Ue 50dBV; fmod = 1kHz; Oscilloscope to Loudspreaker Output. FM; Signal Generator with exact frequency to FM Aerial Input (alternatively: Radio Station). Digital Voltmeter between Testpoints D and E. FM; Signal Generator to FM Aerial Input; Ue = 50dBV; fmod = 19kHz; Oscilloscope to Loudspreaker Outputs. Adjust with T105 a for Maximum. Adjust with T103 b for 1.7V 0.05V. Adjust alternating with T101 c at 603kHz and with TC101 d at 1404kHz for AF Maximum. Adjust with T106 e for 0V 0.04V. Adjust with T107 g (left channel) and with T108 f (right channel) for AF Minimum. a b c d e g f A ED B Abgleichvorschriften / Adjustment ProceduresUMS 200 2 - 5GRUNDIG Service Cassette Test equipment: Frequency Counter, Oscilloscope, Test Cassette 3.15kHz/10kHz (e.g. 448) AdjustmentPreparation Adjustment Procedure 1. Bias Oscillator 2. Bias Voltage 3. Azimuth 4. Tape Speed Frequency Counter to Testpoint F. Insert empty Cassette and start recording. Insert empty Cassette and start recording. Right Channel: Oscilloscope to Testpoint L. Left Channel: Oscilloscope to Testpoint M. Oscilloscope to Loudspreaker Output. Insert Test Cassette and play 10kHz part. Frequency Counter to Loudspreaker Output. Insert Test Cassette and play 3.15kHz part. Adjust with T301 k for 100kHz 5kHz. Adjust with VR301 s for 11Vrms (31Vpp) 0.5V. Adjust with VR302 t for 11Vrms (31Vpp) 0.5V. Adjust at “TAPE “ with Head Screw m for maximal and equal level on both channels. Adjust at “TAPE <“ with Head Screw n for maximal and equal level o

    注意事项

    本文(GrundigUMS200 维修电路图、原理图.pdf)为本站会员(cc518)主动上传,收音机爱好者资料库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知收音机爱好者资料库(点击联系客服),我们立即给予删除!

    温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




    ADZZ
    关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

    copyright@ 2008-2025 收音机爱好者资料库 版权所有
    备案编号:鄂ICP备16009402-5号

    收起
    展开