GrundigSonoclock52SC5302 维修电路图、原理图.pdf
-
资源ID:110000
资源大小:1.92MB
全文页数:10页
- 资源格式: PDF
下载积分:18积分
会员登录下载
三方登录下载:
友情提示
2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,就可以正常下载了。
3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰。
5、试题试卷类文档,如果标题没有明确说明有答案则都视为没有答案,请知晓。
|
GrundigSonoclock52SC5302 维修电路图、原理图.pdf
Sonoclock 52 SC 5302 Service Document Exchange Set Es gelten die Vorschriften und Sicherheitshinweise gem dem Service Manual Sicherheit, Material- nummer 720108000000, sowie zustzlich die even- tuell abweichenden, landesspezifischen Vorschrif- ten! The regulations and safety instructions shall be valid as provided by the Safety Service Manual, part number 720108000000, as well as the respective national deviations. S Dieses Service Dokument ist nur in Datenform verfgbar This Service Document is only available as data nderungen vorbehalten/Subject to alteration Made by GRUNDIG in Germany H-S43 0303 S Service Manual Sicherheit Safety Materialnr./Part No. 720108000000 ? Sonoclock 52 SC 5302? Sonoclock 52 SC 5302? Sonoclock 52 SC 5302? Sonoclock 52 SC 5302? Sonoclock 52 SC 5302? Sonoclock 52 SC 5302? Sonoclock 52 SC 5302? Sonoclock 52 SC 5302? EQUIPMENT REQUIRED Signal Source 1. FM signal generator (FM SG) 2. Sweep generator (10.7 Mhz for FM) Output Indicator 1. SSVM 2. Oscilloscope 3. Frequency Counter General preparation 1. Check source voltage. 2. Set function switch to band being aligned 3. Turn volume control to minimum (unless noted otherwise) 4. Connect low side of signal and output indicator to chassis ground unless otherwise specified. Keep ground connection close to high side connection. 5. Keep signal inout as low as possible to avoid and AFC action (set output indicator to high sensitivity.) 6. Standard modulation is 1000 Hz AT 22.5KHZ amplitude for FM FM ALIGNMENT PROCEDURE Step Signal source (FM RF Gen.) Connect to Set signal to Alignment Indicator connect to Oscilloscope or SSVM Set Radio dial to AdjustAdjust forRemarks 1T1Maximum Symmetrical response 2det. Coil Symmetrical response centered 10.7Mhz 3Repeat Step 1 and 2 as necessary to obtain S curve linearity , with maximum output FM RF ALIGNMENT Step Signal source (FM Signal Gen.) Connect to Set signal to Alignment indicator (oscilloscope , VTVM Connect to Set radio dial to AdjustAdjust for Remarks 1 87.35 MHz modulated 87.35MHz (lowest end) L7 (Osc, coil) 2 108.25MHz modulated 108.25MHz (Highest end) C2 (Osc, trimmer) 3 90 MHz modulated 90MHz L3 (RF coil) stretch or squeeze 4 106 MHz modulated 106MHzC1 (RF trim) 5repeat steps 3 and 4 as necessary to minimum tracking error. Also repeat steps 1 and 2 if necessary. * UK models must not be able to tune below 87.5 MHz. Quiet point ALIGNMENT PROCEDURE MODEL NO. GRUNDIG SONOCLOCK SC 52 Volume control min- position TP2 and GND Sweep centered 10.7 MHz TP3 Detector Output Terminal TP 1, GND (Test point) through matching network if necessary Across speaker voice coilMaximum Volume control Max- position Sonoclock 52 SC 5302? 1 9 8 12 19 7 24 10 23 38 18 13 14 5 2830 33 25 3 34 26 31 39 40 29 274 371617153611 35 20 21 22 32 2 6